Message type: E = Error
Message class: EPRO - Messages for EDM Profile Processing
Message number: 724
Message text: No control meter found for replacement value procedure &1
This replacement value procedure allows you to replace missing values
using the control meter.
The system finds control registers by looking for registers allocated
to profile &v2&. The system then determines the control register for
each of the registers found.
In this case, the system did not find any control meters from &v3& to
&v4&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you want to use this procedure for this profile, you have to create
register relationships accordingly.
Error message extract from SAP system. Copyright SAP SE.
EPRO724
- No control meter found for replacement value procedure &1 ?The SAP error message EPRO724 "No control meter found for replacement value procedure &1" typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with meter readings and replacement value procedures.
Cause: This error generally indicates that the system is unable to find a control meter associated with the specified replacement value procedure. This can happen due to several reasons: Missing Control Meter: The control meter that should be linked to the replacement value procedure is not defined in the system. Incorrect Configuration: The configuration settings for the replacement value procedure may not be set up correctly. Data Inconsistency: There may be inconsistencies in the master data related to the meter or the replacement value procedure. Authorization Issues: The user may not have the necessary authorizations to access the control meter data.
Solution: To resolve the EPRO724 error, you can take the following steps: Check Control Meter Configuration: Go to the configuration settings
Get instant SAP help. Sign up for our Free Essentials Plan.
EPRO723
Replacement value proc. &1: No missing values in reference consump.period
What causes this issue? You entered a reference period from &v3& to &v4&. However, this period does not contain any missing values fo...
EPRO722
Replacement value proc. &1: Manual input required
What causes this issue? You attempted to generate replacement values for profile &v2&. This replacement procedure requires you to enter value...
EPRO725
Replacement value procedure &1: Day type &2 does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EPRO726
Replacement value procedure &1: Factory calendar does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.