Do you have any question about this error?
Message type: E = Error
Message class: EN - IS-U installation/installation structure
Message number: 284
Message text: Breaker &1 material &2 does not have remote disconnection capability
The breaker you selected does not have remote disconnection
capabilities.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Carry out one of the following steps::
Select a breaker that does have remote disconnection capabilities.
Check the function group that is allocated to the breaker and change it
if necessary.
You can find the function group in the <DS:TRAN.EG42>Device Modification
</> transaction, on the <ZK>AMI Data</> tab page in field <ZK>AMCG</>.
Check the function group settings and change them if necessary.
You can change the function group settings in Customizing for <ZK>SAP
Utilities</> under: <ZK>Advanced Metering Infrastructure -> Basic
Settings -> Define Advanced Meter Capabilities</>. In the activity
screen, in the dialog structure, choose the <ZK>Function Group of Device
</> node.
<ZH>Important</>
The changes you make to the function group settings can have an effect
on the capabilities of other device connected to the group.
Error message extract from SAP system. Copyright SAP SE.
EN284
- Breaker &1 material &2 does not have remote disconnection capability ?The SAP error message EN284 indicates that a specific circuit breaker (identified by the breaker number &1) associated with a material (identified by the material number &2) does not have the capability for remote disconnection. This error typically arises in the context of electrical engineering or maintenance management within SAP, particularly when dealing with equipment or materials that are part of a plant maintenance or asset management module.
Cause:
- Configuration Issue: The circuit breaker may not be configured correctly in the system to support remote disconnection. This could be due to missing settings or parameters in the material master or equipment master data.
- Material Master Data: The material associated with the circuit breaker may not have the necessary attributes or classifications that enable remote disconnection.
- Technical Limitations: The specific type of circuit breaker may inherently lack the capability for remote disconnection, either due to its design or specifications.
Solution:
- Check Material Master Data: Review the material master data for the circuit breaker. Ensure that the relevant fields for remote disconnection capability are correctly filled out. This may include checking the classification and attributes of the material.
- Update Configuration: If the circuit breaker should support remote disconnection, ensure that the configuration settings in SAP are updated accordingly. This may involve working with your SAP Basis or technical team to adjust the settings.
- Consult Documentation: Refer to the technical documentation or specifications for the circuit breaker to confirm whether it is designed for remote disconnection. If it is not, you may need to consider using a different breaker that supports this feature.
- SAP Notes and Support: Check for any SAP Notes related to this error message. SAP may have provided updates or patches that address this issue. If necessary, contact SAP support for further assistance.
Related Information:
By following these steps, you should be able to resolve the EN284 error and ensure that the circuit breaker is correctly configured for remote disconnection capability.
Get instant SAP help. Start your 7-day free trial now.
EN283
Device &1 material &2 is already allocated to a breaker
What causes this issue? The meter is already controlled by another breaker. A meter can only be controlled by one breaker in any given period.System ...
EN282
The device &1 material &2 must be a meter
What causes this issue? You are trying to use a breaker to control a meter that has remote disconnection capabilities. Breakers can only control elec...
EN285
Breaker &1 material &2 does not have remote reconnection capability
What causes this issue? The breaker that you selected does not have remote reconnection capabilities.System Response The system issues an error mess...
EN286
Material &1 does not have values for fields AMCGBestGrp and AMSBestGrp
What causes this issue? Values for the advanced metering system determination group (AMSDG) and the AMCG Determination Group (AMCGDG) are missing for...
Click on this link to search all SAP messages.