Message type: E = Error
Message class: EN - IS-U installation/installation structure
Message number: 253
Message text: Active/reactive indicators of allocated registers do not match
The reactive/active indicator of the registers allocated (old: &V1&,
new: &V2&) do not match.
The logical number cannot be used.
Enter a logical register number with the correct reactive/active
indicator.
Error message extract from SAP system. Copyright SAP SE.
EN253
- Active/reactive indicators of allocated registers do not match ?The SAP error message EN253, which states "Active/reactive indicators of allocated registers do not match," typically occurs in the context of energy management or utility billing within the SAP system, particularly when dealing with meter readings and allocation of energy consumption.
Cause:
This error usually arises when there is a mismatch between the active and reactive indicators of the registers that have been allocated for a particular meter. In energy management, meters can measure both active power (real power) and reactive power (reactive power). If the configuration of the registers does not align correctly (for example, if a register is set to measure active power but is being treated as a reactive power register), this inconsistency triggers the error.
Solution:
To resolve the EN253 error, you can follow these steps:
Check Meter Configuration:
- Go to the configuration settings of the meter in question and verify the settings for active and reactive registers. Ensure that the registers are correctly defined and that their indicators match the intended use.
Review Allocation Settings:
- Check the allocation settings for the meter readings. Ensure that the active and reactive registers are correctly allocated and that their indicators are consistent.
Correct Mismatches:
- If you find any mismatches in the configuration or allocation, correct them. This may involve changing the register type or re-allocating the registers to ensure they match the expected indicators.
Reprocess Data:
- After making the necessary corrections, reprocess the data or transactions that triggered the error. This may involve re-running the billing or allocation process.
Consult Documentation:
- If the issue persists, consult the SAP documentation or help resources specific to your version of SAP. There may be additional troubleshooting steps or configuration settings that need to be addressed.
Seek Support:
- If you are unable to resolve the issue on your own, consider reaching out to your SAP support team or consulting with an SAP expert who specializes in energy management or utility billing.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the EN253 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
EN252
Division categories of the registers allocated do not match
What causes this issue? The division categories of the registers allocated (old :&V1& new:&V2&) do not match.System Response The log...
EN251
You cannot install devices in outline contract installation &1
What causes this issue? You cannot install devices in installation &V1& as this is not permitted for outline contract installations.System Re...
EN254
Division category (&1) of &2 &3 is invalid
What causes this issue? You have attempted to allocate &V2& &V3& to device &V4&. This is not possible because the devices do ...
EN255
Device allocations could not be changed
What causes this issue? The changes you have made require changes to existing device allocations that could not be made automatically.System Response...
Click on this link to search all SAP messages.