Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 678
Message text: Total of places before and after decimal point &1 can be a maximum of &2
The total number of places before and after the decimal point exceeds
the permitted maximum.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Enter a lower number.
Error message extract from SAP system. Copyright SAP SE.
EL678
- Total of places before and after decimal point &1 can be a maximum of &2 ?The SAP error message EL678 indicates that there is an issue with the number of digits allowed before and after the decimal point in a numeric field. Specifically, the message states that the total number of places (digits) before and after the decimal point exceeds the maximum allowed limit.
Cause:
This error typically occurs when:
- A numeric value being entered or processed exceeds the defined length for that field in the database or application.
- The configuration settings for the field (like currency or quantity) do not match the input data.
- The data being imported or processed from an external source has a format that does not comply with the expected format in SAP.
Solution:
To resolve the EL678 error, you can take the following steps:
Check Field Lengths: Review the field definitions in the relevant data structure (like a table or a screen) to understand the maximum allowed digits before and after the decimal point. Adjust your input accordingly.
Data Validation: Ensure that the data being entered or imported adheres to the defined formats. For example, if a field allows a maximum of 10 digits in total with 2 decimal places, the input should not exceed 8 digits before the decimal point.
Adjust Input Values: If you are manually entering data, ensure that the values you are inputting do not exceed the allowed limits. If you are importing data, consider preprocessing the data to ensure compliance.
Configuration Settings: If the error is related to a specific configuration (like currency settings), check the configuration in the relevant transaction (e.g., OB08 for currency settings) to ensure that it matches the expected input.
Consult Documentation: Refer to SAP documentation or help resources for specific details about the field in question, including any relevant notes or guidelines.
Testing: After making adjustments, test the input again to ensure that the error does not reoccur.
Related Information:
By following these steps, you should be able to identify the cause of the EL678 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL677
The number of predecimal places &1 is higher than permitted maximum &2
What causes this issue? The number of places before the decimal point is higher than the permitted maximum.System Response The system issues an erro...
EL676
The meter reading difference exceeds the capacity of the register
What causes this issue? You entered consumption. This consumption is converted into a meter reading, and is stored in the field <LS>Meter Readi...
EL679
No. of predecimal places (&1) does not equal those of register group (&2)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL680
Number of decimal places &1 does not correspond to the reg. group &2
What causes this issue? The number of places after the decimal in a register is defined in the register group. This number can be overridden if a met...
Click on this link to search all SAP messages.