Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 468
Message text: Device &1, Reg. &2: Enter all devices for an installation at same MR time
One of the following errors has occurred:
The device has several registers with meter readings that must be
entered on the same date and at the same time
Installation &v3& contains other devices with meter readings that must
be entered on the same date but at a different time
This leads to problems in billing (conflicting cases).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Change the meter reading time to &v4&.
Change the meter reading time of the registers that have already been
entered and that belong to the same installation.
Error message extract from SAP system. Copyright SAP SE.
EL468
- Device &1, Reg. &2: Enter all devices for an installation at same MR time ?The SAP error message EL468 indicates that there is an issue with the registration of devices for an installation in the context of meter reading (MR) processing. Specifically, it suggests that not all devices associated with a particular installation have been entered at the same meter reading time.
Cause: The error typically arises in the following scenarios: Incomplete Data Entry: When entering meter readings for an installation, if not all devices (e.g., electricity, gas, water meters) are recorded at the same time, this error will occur.
Configuration Issues: There may be configuration settings in the SAP system that require all devices to be registered simultaneously for a given installation. Data Consistency: The system enforces data consistency rules that require all devices to be processed together to ensure accurate billing and reporting.
Solution: To resolve the EL468 error, you can take the following steps: Check Meter Readings: Ensure that all devices associated with the installation are entered at the
Get instant SAP help. Sign up for our Free Essentials Plan.
EL467
Future meter reading orders without unique allocation to an installation
What causes this issue? When you enter meter reading results for device removal, the system checks whether meter reading orders still exist for after...
EL466
Placeholder missing in note text
What causes this issue? No placeholder (<LS>$</>) has been set in the note text (required for an additional text).System Response The sy...
EL469
Dev.&1, Reg.&2: MR time at move-in must be after MR time at move-out (&3)
What causes this issue? The meter reading time at move-in that you entered for device &v1& with register &v2& is earlier than the met...
EL470
Dev.&1,Reg.&2: MR move-out time must be earlier than move-in MR time (&3)
What causes this issue? The meter reading time at move-out that you entered for device &v1& with register &v2& is earlier than the me...
Click on this link to search all SAP messages.