Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 224
Message text: This value is not permissible: each time slice must be closed
A register can be installed in several installations that in turn can
be in different meter reading units with different base periods.
Several base periods categories - and therefore several base periods -
can be allocated to one register. The length of the base period is very
important for calculating expected values because different base
periods may also have different weighting totals, yielding different
forecast values. The period consumption entered would also yield
different forecast values, depending on the base period that you
define.
A register must have the same expected consumption, even if it has
different base periods. You must always specify the period in which
period consumption is valid. Period consumption is no longer based on
the base period of the meter reading unit, but defined for each
register for a certain period.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Specify the period and define period consumption accordingly.
Error message extract from SAP system. Copyright SAP SE.
EL224
- This value is not permissible: each time slice must be closed ?The SAP error message EL224 ("This value is not permissible: each time slice must be closed") typically occurs in the context of SAP's Event Management or similar modules where time slices are used to manage and track events or processes over specific periods.
Cause:
The error indicates that there is an issue with the time slice configuration or data entry. Specifically, it suggests that the time slice you are trying to work with is not properly closed, meaning that the data for that time period has not been finalized or completed. This can happen due to:
- Incomplete Data Entry: The required data for the time slice has not been fully entered or saved.
- Open Time Slice: The time slice is still open for modifications, and the system does not allow further changes until it is closed.
- Configuration Issues: There may be settings in the system that dictate how time slices are managed, and these may not be correctly configured.
Solution:
To resolve the EL224 error, you can take the following steps:
Check Time Slice Status: Verify the status of the time slice you are working with. Ensure that it is closed and that all necessary data has been entered.
Complete Data Entry: If the time slice is open, complete any required entries and save the data. Ensure that all mandatory fields are filled out.
Close the Time Slice: If you have the necessary permissions, close the time slice in question. This may involve navigating to the relevant transaction or screen in SAP and selecting the option to close the time slice.
Review Configuration: If the issue persists, review the configuration settings related to time slices in your SAP system. Consult with your SAP administrator or functional consultant to ensure that the settings align with your business processes.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on managing time slices in your version of SAP.
Seek Support: If you are unable to resolve the issue, consider reaching out to your SAP support team or consulting SAP Notes for any known issues or patches related to this error.
Related Information:
By following these steps, you should be able to identify the cause of the EL224 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL223
&1 device &2, MR date &3: Estimated more than &4 times -> reset reading
What causes this issue? The permitted number of successive estimations was exceeded. The permitted number of estimations is defined in the installati...
EL222
Transfer parameters &2 &3 missing in FM &1.
What causes this issue? Error during the transfer of parameters in the extrapolation function module.System Response Extrapolation is not possible, ...
EL225
Error during extrapolation of device &1, register &2 in installation &3
What causes this issue? During extrapolation, you attempted to calculate the linear portion from the actual consumption according to the installation...
EL226
The contract is not allocated to the installation
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.