Message type: E = Error
Message class:  EL - IS-U meter reading data processing 
Message number: 163
Message text: Device &1 MR date &2: Number of usage hours exceeds maximum value
During validation 13, it was determined that the number of permissible
usage hours was exceeded. The number of permissible usage hours is
calculated by dividing the consumption by the installed demand. The
installed demand is stored in an operand. Via the check class, this
operand is set in table TE409 in the field BENUTZSTD.
The maximum permissible usage hours corresponds to the number of hours
that have expired since the last reading.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Example: TE409-BENUTZSTD = INSLEIST = 20 kWThe meter reading can be released or reset for a later correction.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message EL163 indicates that the number of usage hours recorded for a device (in this case, a measuring point) has exceeded the maximum value set in the system. This typically occurs in the context of equipment or asset management, where usage hours are tracked for maintenance and operational purposes.
Cause: Exceeded Usage Hours: The primary cause of this error is that the recorded usage hours for the device have surpassed the predefined maximum limit set in the system.
Configuration Issues: The maximum usage hours may not be configured correctly, or the device may not have been set up properly in the system. Data Entry Errors: Incorrect data entry or system errors may lead to inflated usage hours being recorded.
Solution: Check Configuration: Review the configuration settings for the device in question. Ensure that the maximum usage hours are set appropriately based on operational requirements. Navigate to the relevant configuration settings in SAP (e.g., transaction
 Get instant SAP help. Sign up for our Free Essentials Plan.
Get instant SAP help. Sign up for our Free Essentials Plan. 
EL162 No weighting key was allocated to operand &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL161 Create weighting key with GEWVERF = '01' in table TE266
What causes this issue?  No weighting key must be specified in the rate for wattregisters. However, for the extrapolation of wattregisters, you need a...
EL164 Function module for printing meter reading docs was called incorrectly
What causes this issue?  Depending on the form class, the following parameters must be transferred: Meter reading order: One meter reading unit       ...
EL165 Scheduled meter reading date may not be in the past
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.