Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 076
Message text: Entry &1 &2 &3 &4: valid from consumption <> 0
The valid-from consumption of the first entry of the consumption
interval must be 0.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL076
- Entry &1 &2 &3 &4: valid from consumption <> 0 ?The SAP error message EL076 indicates that there is an issue with the consumption of a material or resource in the system. Specifically, the message states that the "valid from consumption" is not equal to zero, which typically means that there is a discrepancy in the consumption data for a particular material or resource.
Cause:
- Incorrect Configuration: The configuration settings for the material or resource may not be set up correctly, leading to inconsistencies in consumption data.
- Data Entry Errors: Manual data entry errors can lead to incorrect values being recorded for consumption.
- Master Data Issues: Problems with the master data of the material or resource, such as incorrect validity periods or status settings.
- Transaction Errors: Errors during transactions that involve consumption, such as goods movements or production orders, can lead to this message being triggered.
Solution:
- Check Configuration: Review the configuration settings for the material or resource in question. Ensure that all settings related to consumption are correctly defined.
- Review Master Data: Check the master data for the material or resource. Ensure that the validity periods and other relevant fields are correctly set.
- Correct Data Entry: If the error is due to manual data entry, correct the entries in the relevant transactions or master data records.
- Analyze Transactions: Look into the transactions that led to this error. Check for any inconsistencies or errors in the consumption postings.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the error message and its implications.
Related Information:
MM03
(Display Material), MB51
(Material Document List), or CO03
(Display Production Order) to investigate the issue further.By following these steps, you should be able to identify the root cause of the EL076 error and implement the necessary corrections to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL075
Division &1 (division category &2) is not permitted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL074
Specify a weighting key
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL077
Entry &1 &2 &3 &4: valid to consumption <> 99.999.999.999.999.999
What causes this issue? The valid-to consumption of the last entry of a consumption interval must be 99.999.999.999.999.999.System Response The syst...
EL078
Entry &1 &2 &3 &4: incomplete consumption intervals
What causes this issue? Within a consumption interval, the valid-from consumption of an entry has to be 1 larger than the valid-to consumption of the...
Click on this link to search all SAP messages.