Do you have any question about this error?
Message type: E = Error
Message class: EHSB_RC - Compliance Check
Message number: 127
Message text: Units of meas. that cannot be converted into each other in subst. grp &1
Substance group with constraints &v1& contains substances that have
units of measurement in the explosion result that the system cannot
convert into each other.
The system cannot perform the compliance check.
Make sure that the substance group with constraints only contains
substances that have units of measurement in the explosion result that
can be converted into each other.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EHSB_RC127
- Units of meas. that cannot be converted into each other in subst. grp &1 ?The SAP error message EHSB_RC127 indicates that there is an issue with the units of measurement (UoM) in a substitution group. Specifically, it means that the units of measurement being used cannot be converted into each other, which is causing a problem in the context of the Environmental, Health, and Safety (EHS) module.
Cause:
- Incompatible Units of Measurement: The error typically arises when you are trying to substitute or convert quantities that use different units of measurement that are not compatible. For example, trying to convert liters to kilograms without a proper conversion factor or context.
- Configuration Issues: There may be a configuration issue in the system where the conversion factors for certain units of measurement are not defined or are incorrect.
- Data Entry Errors: Incorrect data entry in the material master or in the EHS data records can lead to this error.
Solution:
- Check Units of Measurement: Review the units of measurement being used in the substitution group. Ensure that they are compatible and that there is a valid conversion factor defined between them.
- Define Conversion Factors: If the units are supposed to be convertible, check the configuration in the SAP system to ensure that the conversion factors are correctly defined in the relevant tables (e.g., T006 for units of measure).
- Correct Data Entries: Verify the data entries in the material master or EHS records to ensure that the correct units of measurement are being used.
- Consult Documentation: Refer to SAP documentation or help resources for guidance on how to manage units of measurement and conversion factors in the EHS module.
- Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
MM02
(Change Material) or EHS00
(EHS Management) to review and modify the relevant data.By following these steps, you should be able to identify and resolve the issue related to the EHSB_RC127 error message.
Get instant SAP help. Start your 7-day free trial now.
EHSB_RC126
Substance group &1 contains different specification types
What causes this issue? The substance group with constraints &v1& contains substances of different specification types.System Response The s...
EHSB_RC123
Number of checks with status &1 (&2): &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EHSB_RC128
Invalid exception value for component &1
What causes this issue? Exception value &v2& of component &v1& of the product &v3& is in the list of invalid exception valu...
EHSB_RC129
Check the exception value for component &1
What causes this issue? Substance &v1& in the formula for product &v3& has exception value &v2&. The compliance check does &l...