Do you have any question about this error?
Message type: E = Error
Message class: EHPRC_CPM_BOMBOS - Messages for BOMBOS Interface
Message number: 016
Message text: Cannot read environmental parameter &1 from Customizing
Environment parameter &V1& could not be read from the BOM transfer
Customizing.
The error occurred in program &V4&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
In the Customizing activity <LS>Specify Environment Parameters and
Conditions</>, enter the environment parameter &V1&.
Error message extract from SAP system. Copyright SAP SE.
EHPRC_CPM_BOMBOS016
- Cannot read environmental parameter &1 from Customizing ?The SAP error message EHPRC_CPM_BOMBOS016 indicates that the system is unable to read a specific environmental parameter from the Customizing settings. This error typically arises in the context of Environmental Health and Safety (EHS) or related modules where certain parameters are required for processing.
Cause:
- Missing Customizing Entries: The environmental parameter specified by
&1
may not be defined in the Customizing settings.- Authorization Issues: The user may not have the necessary authorizations to access the Customizing settings where the parameter is defined.
- Incorrect Configuration: There may be a misconfiguration in the Customizing settings that prevents the system from retrieving the parameter.
- Transport Issues: If the Customizing settings were recently transported from another system, there may have been issues during the transport process.
Solution:
Check Customizing Settings:
- Navigate to the relevant Customizing transaction (e.g., SPRO) and verify if the environmental parameter is defined correctly.
- Ensure that the parameter exists and is correctly configured.
Review Authorizations:
- Check if the user encountering the error has the necessary authorizations to access the Customizing settings.
- If not, work with your security team to grant the required permissions.
Validate Configuration:
- Review the configuration for any inconsistencies or errors that might prevent the parameter from being read.
- Make sure that all dependencies and related settings are correctly configured.
Transport Check:
- If the issue arose after a transport, check the transport logs for any errors or warnings.
- Ensure that all necessary objects were included in the transport request.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific environmental parameter to understand its purpose and configuration requirements.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. Provide them with the error message details and any relevant configuration information.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EHPRC_CPM_BOMBOS015
Action canceled; exception &2 in function module &1; error in program &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EHPRC_CPM_BOMBOS014
Error while creating a substance for material &1
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. The...
EHPRC_CPM_BOMBOS017
Creation of specification for material &1 canceled in a user exit
What causes this issue? The message was created in program &V4&.System Response The specification was not created. Processing was stopped.Ho...
EHPRC_CPM_BOMBOS018
Error in unit conversion from &1 to &2 for material &3 (exception &4)
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Sys...
Click on this link to search all SAP messages.