Do you have any question about this error?
Message type: E = Error
Message class: EG - IS-U device management
Message number: 479
Message text: The values you have entered for primary and secondary side are too large
You entered values for the primary and secondary ends that cause an
overflow when calculating the transformation ratio. As a result, the
transformation ratio cannot be calculated.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check your entries.
Error message extract from SAP system. Copyright SAP SE.
EG479
- The values you have entered for primary and secondary side are too large ?The SAP error message EG479, which states "The values you have entered for primary and secondary side are too large," typically occurs in the context of configuring or processing data related to equipment, such as in the SAP PM (Plant Maintenance) or SAP PS (Project System) modules. This error indicates that the values entered for certain fields exceed the allowable limits defined in the system.
Causes:
- Exceeding Field Limits: The values entered for primary and secondary sides (often related to measurements, capacities, or dimensions) exceed the maximum limits set in the system configuration.
- Incorrect Data Entry: Users may have mistakenly entered incorrect or unrealistic values.
- Configuration Issues: The system may not be properly configured to handle the expected range of values for the specific application or module.
- Unit of Measure Issues: The values may be entered in an incorrect unit of measure that leads to inflated numbers.
Solutions:
- Check Value Limits: Review the maximum allowable values for the fields in question. This can often be found in the configuration settings or documentation for the specific module you are working with.
- Adjust Input Values: If the values entered are indeed too large, adjust them to fit within the acceptable range.
- Review Configuration: If you believe the values should be valid, check the configuration settings in SAP to ensure that the limits are set appropriately for your business needs.
- Unit of Measure Verification: Ensure that the units of measure used for the values are correct and consistent with what the system expects.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance related to the module you are using.
- Contact Support: If the issue persists and you cannot identify the cause, consider reaching out to your SAP support team or consulting with an SAP expert.
Related Information:
By following these steps, you should be able to identify the cause of the EG479 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
EG478
Enter current
What causes this issue? You have not specified a value for current.System Response You must enter a value for current for the following types of tra...
EG477
Enter voltage
What causes this issue? You have not specified a voltage.System Response You are required to enter voltage in the case of a: voltage transformer/cur...
EG480
Specify at least &1 windings
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
EG481
Winding is locked and cannot be changed
What causes this issue? You attempted to change a blocked winding from a winding group or its position. Processing of windings from a winding group w...
Click on this link to search all SAP messages.