Do you have any question about this error?
Message type: E = Error
Message class: EG - IS-U device management
Message number: 120
Message text: Device category &1 already has group material number &3
Serialization material &V1& for device category &V2& already has
serialization number (group material number) &V3&.
Processing cannot be continued.
Ensure that your entry is correct. If you wish to allocate device
category &V2& to the same serialization group as device category &V1&,
enter serialization material &V3&.
Error message extract from SAP system. Copyright SAP SE.
EG120
- Device category &1 already has group material number &3 ?The SAP error message EG120 indicates that there is an issue with the assignment of a group material number to a device category. Specifically, it means that the device category you are trying to assign already has a group material number associated with it.
Cause:
- Duplicate Assignment: The device category you are trying to use is already linked to a different group material number.
- Configuration Error: There may be a misconfiguration in the device category settings or in the group material number assignments.
- Data Integrity Issues: There could be inconsistencies in the master data that lead to this error.
Solution:
Check Existing Assignments:
- Go to the relevant transaction in SAP (e.g., transaction code OIS2 or similar) to check the current assignments of device categories and group material numbers.
- Identify if the device category is already assigned to a different group material number.
Modify or Remove Existing Assignment:
- If the device category is already assigned to a group material number that you do not need, you can either modify or remove that assignment.
- Ensure that the new assignment you are trying to make does not conflict with existing ones.
Consult Documentation:
- Review the SAP documentation or configuration guides related to device categories and group material numbers to ensure you are following the correct procedures.
Data Consistency Check:
- Perform a data consistency check to ensure that there are no other underlying issues with the master data that could be causing this error.
Contact SAP Support:
- If you are unable to resolve the issue, consider reaching out to SAP support for assistance. They can provide more detailed insights based on your specific configuration and data.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EG115
Device group is no longer consistent/complete
What causes this issue? The current status of the device group is inconsistent.System Response You cannot save the device group with the current sta...
EG114
Device cat. &1 of device &2 does not match the category of the dev. group
What causes this issue? The basic device category from device category &V1& of device &V2& does not match the category of the device ...
EG121
You cannot change the group mat. no; it is still a ref. group mat. no
What causes this issue? The current device category is still a main serialization material within a group of device categories. Therefore, you cannot...
EG122
Cannot change registration ID as group material &1 is blocked by &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.