Do you have any question about this error?
Message type: E = Error
Message class: EEWMHIK - IS-U: Inspections
Message number: 079
Message text: No regional structure group can be determined for connection object &1
Cannot determine a regional structure group for connection object &V1&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check whether a regional structure group is already allocated to
connection object &V1&.
Error message extract from SAP system. Copyright SAP SE.
EEWMHIK079
- No regional structure group can be determined for connection object &1 ?The SAP error message EEWMHIK079 indicates that the system is unable to determine a regional structure group for a specified connection object. This error typically arises in the context of SAP's Environmental Management or Waste Management modules, where regional structure groups are used to categorize and manage various environmental or waste-related data.
Cause:
The error can occur due to several reasons:
- Missing Configuration: The regional structure group may not be defined in the system for the specific connection object.
- Incorrect Data: The connection object may have incorrect or incomplete data that prevents the system from identifying the appropriate regional structure group.
- Master Data Issues: The master data related to the connection object may be incomplete or incorrectly maintained.
- Custom Development: If there are custom developments or enhancements, they might not be correctly handling the regional structure group determination.
Solution:
To resolve the error, you can take the following steps:
Check Configuration:
- Go to the configuration settings for regional structure groups in the relevant module (e.g., Waste Management).
- Ensure that the regional structure group is defined for the connection object in question.
Review Connection Object Data:
- Verify the data of the connection object to ensure that all required fields are filled out correctly.
- Check if the connection object is linked to the correct regional structure group.
Maintain Master Data:
- Ensure that all relevant master data (e.g., locations, plants, etc.) is correctly maintained and linked to the connection object.
Consult Documentation:
- Review SAP documentation or notes related to the specific module you are working with to understand the requirements for regional structure groups.
Debugging:
- If you have access to debugging tools, you can trace the program logic to see where the determination of the regional structure group is failing.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. Provide them with the error message and any relevant details about the connection object.
Related Information:
SPRO
for configuration, or SE11
to check the data dictionary for the connection object.By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EEWMHIK078
No regional structure group can be determined for techn. installation &1
What causes this issue? Cannot determine a regional structure group for technical installation &V1&.System Response The system issues an err...
EEWMHIK077
No regional structure group can be determined for equipment &1
What causes this issue? Cannot determine regional structure group for equipment &V1&.System Response The system issues an error message and ...
EEWMHIK080
No periods determined for technical installation &1 and premise &2
What causes this issue? Cannot determine inspection periods for technical installation &V1& and premise type &V2&. These periods are ...
EEWMHIK081
Next insp. for tech. installation &1 on &2 is not in the campaign period
What causes this issue? The next inspection date for <DS:GLOS.36B21A7EFBAA63CDE10000009B38F9B7>technical installation</> &V1& is ...
Click on this link to search all SAP messages.