Do you have any question about this error?
Message type: E = Error
Message class: EEDMSET - Messages for Settlement
Message number: 614
Message text: Parameter &2 cannot be allocated to a register of point of delivery &1
No suitable interval meters are allocated to point of delivery &V1&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Remove the device allocation to point of delivery &V1& or allocate a
device information record that contains a suitable interval meter
(interval length &V3&).
Restart the wizard to create the missing profile parameters.
Error message extract from SAP system. Copyright SAP SE.
EEDMSET614
- Parameter &2 cannot be allocated to a register of point of delivery &1 ?The SAP error message EEDMSET614 indicates that there is an issue with the allocation of a parameter to a register for a specific point of delivery (POD). This error typically arises in the context of SAP's Energy Data Management (EDM) or similar modules where data related to energy consumption, billing, or meter readings is processed.
Cause:
The error can occur due to several reasons, including:
Incorrect Configuration: The parameter being allocated may not be correctly configured in the system. This could be due to missing or incorrect settings in the master data for the point of delivery.
Data Inconsistencies: There may be inconsistencies in the data related to the point of delivery, such as missing entries in the relevant tables or incorrect relationships between the POD and the parameters.
Parameter Restrictions: The parameter you are trying to allocate may not be valid for the specific type of register or point of delivery. Each register may have specific parameters that it can accept.
Authorization Issues: There may be authorization issues preventing the allocation of the parameter to the register.
Solution:
To resolve the error, you can take the following steps:
Check Configuration: Review the configuration settings for the point of delivery and ensure that all necessary parameters are correctly defined. This includes checking the master data for the POD and the associated registers.
Validate Data: Ensure that there are no inconsistencies in the data. Check the relevant tables for the point of delivery and the parameters to ensure that all required entries are present and correctly linked.
Review Parameter Validity: Verify that the parameter you are trying to allocate is valid for the specific register type. Consult the documentation or configuration guides for the specific module you are working with.
Check Authorizations: Ensure that you have the necessary authorizations to perform the allocation. If you suspect authorization issues, consult with your SAP security team.
Consult SAP Notes: Check the SAP Support Portal for any relevant SAP Notes or updates that may address this specific error message. There may be patches or updates that resolve known issues.
Debugging: If you have access to debugging tools, you can trace the execution to identify where the error is occurring in the code. This may provide additional insights into the root cause.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the EEDMSET614 error message in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
EEDMSET613
Cannot create device information record for &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EEDMSET612
You have not specified a device cat. for creating the device info record
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EEDMSET615
Customizing for input parameter or event missing in procedure &1
What causes this issue? You want to check the parameter allocation for settlement procedure &V1&. Processing is terminated because the Custom...
EEDMSET616
In procedure &1 Customizing for parameters &2 and &3 is not unique
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.