Do you have any question about this error?
Message type: E = Error
Message class: EEDMCOM - Messages for EDM Communication Components
Message number: 003
Message text: Inconsistent unit of measurement for profile values
Different units of measure - &v2& and &v3& - appear in the profile
values that you attempted to transfer to profile &v1&.
The identical unit of measure must be used for all profile values in
order to enable their transfer.
INCLUDE ISU_VERARB OBJECT DOKU ID TX
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EEDMCOM003
- Inconsistent unit of measurement for profile values ?The SAP error message EEDMCOM003 indicates that there is an inconsistency in the unit of measurement (UoM) for profile values in the context of data management, particularly in the Energy Data Management (EDM) module. This error typically arises when the system encounters different units of measurement for the same profile or data set, which can lead to confusion and incorrect data processing.
Cause:
- Mismatched Units: The most common cause is that the profile values are defined with different units of measurement. For example, one value might be in kilowatt-hours (kWh) while another is in megawatt-hours (MWh).
- Configuration Issues: Incorrect configuration in the master data or in the settings for the specific profiles can lead to this inconsistency.
- Data Import Errors: If data is imported from external sources, it may not have consistent units of measurement, leading to this error.
- Manual Data Entry: Manual entry of data can also lead to inconsistencies if users do not adhere to the required units.
Solution:
- Check Profile Configuration: Review the configuration of the profiles in the system to ensure that all values are using the same unit of measurement. This can typically be done in the master data settings.
- Standardize Units: Ensure that all data entries conform to a standard unit of measurement. If necessary, convert values to a common unit before entering them into the system.
- Data Validation: Implement validation checks during data entry or import processes to catch inconsistencies before they lead to errors.
- Review Data Sources: If data is being imported from external systems, ensure that the source data is consistent and correctly formatted.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidelines on handling units of measurement in your version of SAP.
Related Information:
By addressing the root cause of the inconsistency and ensuring that all profile values are standardized, you can resolve the EEDMCOM003 error and prevent it from occurring in the future.
Get instant SAP help. Start your 7-day free trial now.
EEDMCOM002
Internal error processing IDoc &1
What causes this issue? An internal error occurred during processing of IDoc &v1&.System Response The system issues an error message and wil...
EEDMCOM001
Structure error in IDoc &1
What causes this issue? IDoc &v1& has an incorrect structure. The structure does not correspond to structure prescribed by format &v2&...
EEDMCOM004
Profile values incorrectly transferred
What causes this issue? The profile values transferred for profile &v1& contain inconsistent time information. This is due to one of the foll...
EEDMCOM005
Profile &1 could not be processed
What causes this issue? The system could not transfer the data for profile &v1&.System Response The system issues an error message and will ...
Click on this link to search all SAP messages.