Do you have any question about this error?
Message type: E = Error
Message class: EAMS_BO - Business Object Layer
Message number: 136
Message text: An overflow was triggered by measuring point &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
EAMS_BO136
- An overflow was triggered by measuring point &1 ?The SAP error message EAMS_BO136, which states "An overflow was triggered by measuring point &1," typically occurs in the context of Asset Management or Plant Maintenance modules when dealing with measuring points or counters. This error indicates that a measurement value has exceeded the maximum limit that can be stored or processed, leading to an overflow condition.
Cause:
Exceeding Maximum Value: The most common cause of this error is that the measurement point has recorded a value that exceeds the defined maximum limit for that measurement type. This can happen if:
- The measurement point is not properly configured.
- There is a data entry error where an excessively high value is entered.
- The measurement point has been in use for a long time, and the cumulative values have exceeded the storage capacity.
Data Type Limitations: The data type used for storing the measurement values may have a limited range (e.g., integer types), and if the value exceeds this range, it can trigger an overflow.
Solution:
Check Measurement Point Configuration: Review the configuration of the measuring point in the system. Ensure that the maximum allowable values are set correctly and that they align with the expected operational limits.
Data Entry Validation: Implement validation checks during data entry to prevent users from entering values that exceed the maximum limits. This can include setting up input masks or validation rules.
Adjust Measurement Point Limits: If the measurement point is expected to handle larger values, consider adjusting the configuration to allow for higher limits. This may involve changing the data type or increasing the maximum value settings.
Data Cleanup: If the overflow is due to cumulative values, consider resetting or archiving old measurement data if it is no longer needed. This can help prevent future overflows.
Consult Documentation: Refer to SAP documentation or support resources for specific guidelines on handling measurement points and overflow errors.
Contact SAP Support: If the issue persists after checking configurations and data entries, it may be necessary to contact SAP support for further assistance. They can provide insights based on the specific version and configuration of your SAP system.
Related Information:
By addressing the root cause of the overflow and implementing preventive measures, you can minimize the occurrence of this error in the future.
Get instant SAP help. Start your 7-day free trial now.
EAMS_BO135
Measuring point &1 does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EAMS_BO134
2 measurement readings exist for measuring point &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EAMS_BO137
Error while trying to access measurement reading &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EAMS_BO138
Measurement reading &1 has already been saved and cannot be deleted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.