Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: /EACA/PMRT -
Message number: 123
Message text: Characteristic &1 is superfluous in the entry variant
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/EACA/PMRT123
- Characteristic &1 is superfluous in the entry variant ?The SAP error message
/EACA/PMRT123 Characteristic &1 is superfluous in the entry variant
typically occurs in the context of variant configuration or when working with characteristics in a product model. This error indicates that a characteristic that has been included in the entry variant is not necessary or is redundant based on the current configuration settings.Cause:
- Redundant Characteristic: The characteristic specified in the error message is not needed for the current configuration of the product. This can happen if the characteristic is not relevant for the selected values or if it has been marked as optional but is still included in the entry variant.
- Configuration Settings: The configuration settings may have changed, making the characteristic no longer applicable.
- Incorrect Entry Variant: The entry variant may have been incorrectly defined, including characteristics that are not required for the specific product configuration.
Solution:
- Review Entry Variant: Check the entry variant configuration to ensure that only the necessary characteristics are included. Remove any characteristics that are not required.
- Adjust Characteristics: If the characteristic is indeed needed, verify its settings in the configuration profile. Ensure that it is marked as required if it should be mandatory.
- Check Dependencies: Review any dependencies or constraints associated with the characteristics. Sometimes, characteristics are dependent on others, and if those dependencies are not met, it can lead to this error.
- Consult Documentation: Refer to the SAP documentation or help resources for guidance on configuring entry variants and characteristics.
- Testing: After making changes, test the configuration to ensure that the error does not reoccur and that the product can be configured as expected.
Related Information:
CU50
(Configuration Profile) or CU01
(Create Characteristics) to manage characteristics and entry variants.By following these steps, you should be able to resolve the error and ensure that your entry variant is correctly configured.
Get instant SAP help. Sign up for our Free Essentials Plan.
/EACA/PMRT122
Characteristic value &1 is different to char. value &2 from entry variant
What causes this issue? You want to use a line item that has already been posted as a template. The predefined characteristics in the entry variant d...
/EACA/PMRT121
Characteristic &1, parent of characteristic &2, is not in the group
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/EACA/PMRT124
Source document &1 is a reversal document - no doc. info can be displayed
What causes this issue? Source document &V1& is not a reversal document. For this reason, no origin information can be displayed. Do you want...
/EACA/PMRT125
Entry variants cannot be used (variant &1 is not active)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.