Do you have any question about this error?
Message type: E = Error
Message class: DT - Table activation (incl. indexes)
Message number: 608
Message text: No action taken (Control parameters were inactive)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
DT608
- No action taken (Control parameters were inactive) ?The SAP error message DT608 ("No action taken (Control parameters were inactive)") typically occurs in the context of data transfer or data processing activities within SAP, particularly when dealing with data transfer processes (DTP) or data extraction.
Cause:
The error message DT608 indicates that the control parameters for the data transfer or processing activity are inactive. This can happen for several reasons:
Inactive Control Parameters: The control parameters that govern the data transfer process may not be activated. This could be due to a configuration issue or a change in the settings that has not been properly activated.
Data Source Issues: The data source from which data is being extracted may not be properly configured or may be inactive.
Authorization Issues: The user executing the data transfer may not have the necessary authorizations to perform the action.
Technical Issues: There may be underlying technical issues, such as problems with the data model or inconsistencies in the data.
Solution:
To resolve the DT608 error, you can take the following steps:
Check Control Parameters:
- Go to the relevant transaction (e.g., RSA1 for Data Warehousing Workbench).
- Navigate to the Data Transfer Process (DTP) or InfoPackage that is causing the issue.
- Ensure that the control parameters are active. If they are inactive, activate them.
Review Data Source Configuration:
- Check the configuration of the data source to ensure it is active and properly set up.
- If necessary, reactivate the data source.
Verify Authorizations:
- Ensure that the user executing the process has the necessary authorizations to perform the data transfer.
- Check the roles and authorizations assigned to the user.
Check for Technical Issues:
- Review the logs for any additional error messages or warnings that may provide more context.
- If there are inconsistencies in the data model, consider running consistency checks or reactivating the affected objects.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific version of SAP you are using for any known issues or additional troubleshooting steps.
Contact SAP Support:
- If the issue persists after following the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the DT608 error in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
DT607
Key field & has type &: Buffering not possible, Transport restricted
What causes this issue? A numeric type was used for a key field. A table of this sort cannot be buffered. When buffering, the table records for numer...
DT606
Specifications for number of key fields are deleted
What causes this issue? Generic buffering was selected for this table. A number of key fields had to be specified for the generic key. After changing...
DT609
Value in field & (value & not permitted)
What causes this issue? An incorrect value was defined in field &V1&.System Response The Dictionary object is not activated and not successf...
DT610
Table & is not an active table
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.