Message type: E = Error
Message class: DNO - Messages for General Notifications
Message number: 224
Message text: Message type &1 is not permitted
The message type &V1& that was transferred in the export parameter
E_MESSAGE from your implementation of the method CHANGE_RFC_DATA of the
BAdI DNO_RFC_DATA is not permitted. Therefore, the message
&V2& &V3& is output as an error message.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Change the transferred message type in your implementation.
Error message extract from SAP system. Copyright SAP SE.
DNO224
- Message type &1 is not permitted ?The SAP error message DNO224, which states "Message type &1 is not permitted," typically occurs in the context of SAP's messaging system, particularly when dealing with IDocs (Intermediate Documents) or other message types in the SAP environment. This error indicates that the specified message type is not allowed for the operation you are trying to perform.
Cause:
- Invalid Message Type: The message type you are trying to use is not defined or is not permitted in the current context.
- Configuration Issues: The message type may not be properly configured in the system, or it may not be activated.
- Authorization Issues: The user may not have the necessary authorizations to use the specified message type.
- Incorrect Partner Profile: The partner profile for the IDoc or message type may not be set up correctly, leading to the rejection of the message type.
Solution:
Check Message Type: Verify that the message type you are trying to use is valid and exists in the system. You can do this by checking the relevant configuration in transaction WE81 (Message Types) or WE82 (Message Type/IDoc Type).
Review Partner Profiles: Ensure that the partner profiles (transaction WE20) are correctly configured for the message type you are using. Check if the message type is included in the partner profile and that it is set up for the correct logical system.
Authorization Check: Ensure that the user executing the transaction has the necessary authorizations to use the specified message type. You may need to consult with your security team to verify this.
Configuration in WE30: If you are working with IDocs, check the IDoc type configuration in transaction WE30 to ensure that the message type is correctly associated with the IDoc type.
Consult Documentation: If the message type is part of a specific application or module, consult the relevant SAP documentation or support notes for any additional configuration steps that may be required.
Testing: After making any changes, test the process again to see if the error persists.
Related Information:
If you continue to experience issues after following these steps, it may be beneficial to reach out to your SAP support team or consult with SAP's support resources for further assistance.
Get instant SAP help. Start your 7-day free trial now.
DNO223
Message &1 &2 does not exist
What causes this issue? The message &V1& &V2& that was transferred in the export parameter E_MESSAGE from your implementation of the ...
DNO222
Internal error when sending to the BC: & & &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DNO225
Select at least one status indicator
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DNO230
Error during log-on. User does not belong to partner &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.