Do you have any question about this error?
Message type: E = Error
Message class: DMEE_ABA - Messages for Data Medium Exchange Engine
Message number: 373
Message text: Node &1: constant missing, source value overwritten with initial value
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
DMEE_ABA373
- Node &1: constant missing, source value overwritten with initial value ?The SAP error message DMEE_ABA373 indicates that there is a problem with the DMEE (Data Medium Exchange Engine) configuration, specifically related to the ABA373 format. This error typically occurs when a required constant value is missing in the DMEE tree structure, leading to the source value being overwritten with an initial (default) value.
Cause:
- Missing Constant: The error suggests that a constant that should be defined in the DMEE tree is not present. Constants are used to define fixed values that are required for the output file format.
- Incorrect Configuration: The DMEE tree might be incorrectly configured, leading to the absence of necessary constants.
- Source Value Issues: The source value that is supposed to be populated might not be correctly mapped or defined, causing it to revert to an initial value.
Solution:
Check DMEE Configuration:
- Go to the DMEE transaction (usually DMEE or OBPM).
- Open the relevant DMEE tree for the ABA373 format.
- Verify that all required constants are defined and correctly configured.
Define Missing Constants:
- If you identify any missing constants, add them to the DMEE tree.
- Ensure that the constants are correctly referenced in the nodes where they are needed.
Review Source Value Mapping:
- Check the mapping of source values in the DMEE tree.
- Ensure that the source values are correctly defined and that they point to the right fields in the data structure.
Test the Configuration:
- After making changes, test the DMEE output generation to ensure that the error is resolved.
- Monitor the output file to confirm that the expected values are being populated correctly.
Consult Documentation:
- Refer to SAP documentation or help resources for specific details on the ABA373 format and the required constants.
Related Information:
By following these steps, you should be able to resolve the DMEE_ABA373 error and ensure that your DMEE configuration is set up correctly for generating the desired output.
Get instant SAP help. Start your 7-day free trial now.
DMEE_ABA372
No action node is created for node &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DMEE_ABA371
Node &1: you must define mapping using action nodes or an exit module
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DMEE_ABA374
No aggregation relationships specified for node &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DMEE_ABA375
Error in opt. supplementary segments of node &1: no node with ref. ID &2
What causes this issue? Reference ID &V2& is specified in the optional supplementary segment data for node &V1&. However, this refere...
Click on this link to search all SAP messages.