Message type: E = Error
Message class: DI - Dictionary messages: Indexes
Message number: 796
Message text: Lock field &-& does not have a character-like type
The field named was identified as <DS:TX.DDDOK_ENQU_FIELD>lock field</>
of the lock object. However, its ABAP type is not of character type.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check whether you could give the field another type, perhaps NUMC,
or whether you can remove the field from the key for the table.
Key fields which are not of character type also cause problems elswhere,
for example when transporting table entries.
Error message extract from SAP system. Copyright SAP SE.
DI796
- Lock field &-& does not have a character-like type ?The SAP error message DI796 indicates that there is an issue with a lock field in your SAP system. Specifically, the error message states that the lock field does not have a character-like type, which means that the field being used for locking is not of a compatible data type (e.g., CHAR, VARCHAR) that can be used for locking purposes.
Cause: Data Type Mismatch: The lock field specified in the operation is not of a character-like type. This could happen if the field is defined as a numeric type, date type, or any other non-character type. Incorrect Configuration: The configuration of the locking mechanism may be incorrect, leading to the use of an inappropriate field for locking. Custom Development: If there are custom programs or enhancements, they may be using a field that is not suitable for locking.
Solution: Check Field Definition: Verify the data type of the lock field in the relevant table or structure.
Get instant SAP help. Sign up for our Free Essentials Plan.
DI795
Predecessor table & for base table & does not follow this in hierarchy
What causes this issue? Each secondary table of a lock object must be connected to a base table above it in the hierarchy with a join condition. The ...
DI794
Predecessor table & for base table & is not a base table
What causes this issue? Each secondary table of a lock object must be connected to a base table above it in the hierarchy with a join condition. For ...
DI797
Inconsistent join of basis table & to predecessor table & (check field &)
What causes this issue? Each secondary table of a lock object must be connected to a base table above it in the hierarchy with a join condition. This...
DI798
Parameter field &-& for lock parameter & is not a key field
What causes this issue? A <DS:TX.DDDOK_ENQU_PARAMETER>lock parameter</> of a lock object must always be assigned to a <DS:TX.DDDOK_ENQ...
Click on this link to search all SAP messages.