Message type: E = Error
Message class: DI - Dictionary messages: Indexes
Message number: 787
Message text: Parameter field &-& of lock parameter & is not in base table
A <DS:TX.DDDOK_ENQU_PARAMETER>lock parameter</> of a lock object must
always be assigned to a
<DS:TX.DDDOK_ENQU_PARAMETERFIELD>parameter field</> of the lock object.
No field from a base table was specified for the viewed lock parameter.
The action was cancelled.
Extend the list of base tables accordingly or delete the lock parameter
named.
Error message extract from SAP system. Copyright SAP SE.
DI787
- Parameter field &-& of lock parameter & is not in base table ?The SAP error message DI787 indicates that there is an issue with a parameter field in a lock parameter that is not found in the base table. This error typically arises in the context of data locking mechanisms in SAP, particularly when dealing with database operations that require locking to ensure data integrity.
Cause: Missing Field in Base Table: The specified parameter field is not defined in the base table that is being accessed. This could be due to a misconfiguration or an incorrect reference to a field that does not exist. Incorrect Lock Parameter Configuration: The lock parameter may have been incorrectly set up in the system, leading to a mismatch between the expected fields and the actual fields in the base table. Changes in Table Structure: If the structure of the base table has been changed (e.g., fields added or removed) and the lock parameters have not been updated accordingly, this error
Get instant SAP help. Sign up for our Free Essentials Plan.
DI786
Parameter field &-& of lock parameter & does not exist
What causes this issue? A <DS:TX.DDDOK_ENQU_PARAMETER>lock parameter</> of a lock object must alway be assigned to a <DS:TX.DDDOK_ENQU...
DI785
Parameter field &-& belongs to multiple lock parameters
What causes this issue? A <DS:TX.DDDOK_ENQU_PARAMETER>lock parameter</> of a lock object must always be assigned to a <DS:TX.DDDOK_ENQ...
DI788
Position of base table & incorrectly maintained
What causes this issue? The consecutive numbering of the base tables in the sources is incorrect.System Response A warning was triggered.How to fix ...
DI789
No table can be locked with the lock object
What causes this issue? Because no <DS:TX.DDDOK_ENQU_MODE>lock modes</> are defined for the lock object, no effective lock can be set wit...
Click on this link to search all SAP messages.