Message type: E = Error
Message class: DI - Dictionary messages: Indexes
Message number: 765
Message text: Base table & is assigned to incorrect lock object &
A base table is not assigned to the lock object to be treated.
The action is cancelled.
Establish the consistency of the Dictionary sources of the lock object.
Error message extract from SAP system. Copyright SAP SE.
DI765
- Base table & is assigned to incorrect lock object & ?The SAP error message DI765 indicates that a base table is assigned to an incorrect lock object. This typically occurs in the context of database table locking mechanisms in SAP, which are used to ensure data consistency during concurrent access.
Cause: Incorrect Lock Object Assignment: The error usually arises when a database table is assigned to a lock object that does not match its intended use. This can happen if the lock object was incorrectly defined or if the table was modified without updating the lock object accordingly. Transport Issues: If changes were transported from one system to another (e.g., from development to production), and the lock object was not properly included or updated, this error can occur. Custom Development: If custom development has been done that involves database tables and lock objects, there may be inconsistencies in how they are defined.
Solution: Check Lock Object Assignment: Use transaction code SE11 (Data Dictionary) to check the lock
Get instant SAP help. Sign up for our Free Essentials Plan.
DI764
Incorrect aggregate type & in the header of the lock object
What causes this issue? According to the sources of the object, it is not a lock object but rather an aggregate of another type.System Response The ...
DI763
Incorrect name & in the header of the lock object
What causes this issue? The name of the lock object to be activated does not correspond to the name specified in the header of the lock object.System...
DI766
Inconsistent entry for the primary table of the lock object
What causes this issue? In the sources the entry for the primary tables of the lock object to be activated is inconsistent.System Response The actio...
DI767
Lock object has no base tables
What causes this issue? The lock object treated does not have any based tables. Every lock object must however have at least one base table, namely i...
Click on this link to search all SAP messages.