Message type: E = Error
Message class: DBMAN - Data Manager Message Class
Message number: 976
Message text: &1 is part of a HybridProvider and cannot be filled directly
The InfoCube is part of a HybridProvider. Data can only be loaded in the
HybridProvider using the data transfer process (DTP). Data cannot be
written directly to the InfoCube as part of the HybridProvider.
Writing is terminated.
Only write to the HybridProvider with the DTP.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
DBMAN976
- &1 is part of a HybridProvider and cannot be filled directly ?The SAP error message DBMAN976 indicates that you are trying to fill a data source that is part of a HybridProvider directly, which is not allowed. HybridProviders in SAP BW/4HANA or SAP BW on HANA are designed to combine data from different sources, such as SAP HANA views and traditional InfoProviders, and they manage data loading in a specific way.
Cause: The error occurs when: You attempt to load data directly into a HybridProvider, which is not supported. The HybridProvider is designed to aggregate data from multiple sources, and direct data loading is not part of its functionality.
Solution: To resolve this error, you can follow these steps: Identify the Source: Determine which data source you are trying to load data into the HybridProvider. Ensure that you are not trying to load data directly into the HybridProvider itself. Load Data into Underlying Providers: Instead of loading data directly into the HybridProvider, load the data into the underlying InfoProviders
Get instant SAP help. Sign up for our Free Essentials Plan.
DBMAN975
Error while deleting package &1 from table &2
What causes this issue? An error has occurred while deleting a package from the InfoCube staging table.System Response Next time the deletion is cal...
DBMAN974
The staging table cannot be generated in the update task
What causes this issue? Module RSDRI_CUBE_WRITE_PACKAGE or class CL_RSDRI_INFOCUBE has been called in the update task in order to write data to an In...
DBMAN977
No referential integrity set for filter on attribute &1
What causes this issue? Currently, it cannot be guaranteed that master data exists for all characteristic values of the InfoProvider to be read. Refe...
DBMAN980
No change authorization (S_DEVELOP)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.