Message type: E = Error
Message class: DB6 - DB6: Alert Monitoring and Alert Configuration
Message number: 530
Message text: An invalid value has been returned for the DFT_MON_TABLE switch
To allow meaningful monitoring of the database, you must activate this
switch.
If this switch is not set, it can lead to problems ranging from
restricting the function of the CCMS transactions to erroneous
terminations.
Activate the switch by setting the appropriate database manager
parameters using the following command:
<LB>UPDATE DBM CFG USING DFT_MON_TABLE ON </>
The setting will become active at the next connection to the database.
Error message extract from SAP system. Copyright SAP SE.
DB6530
- An invalid value has been returned for the DFT_MON_TABLE switch ?The SAP error message DB6530 indicates that there is an issue with the DFT_MON_TABLE switch, which is related to database monitoring in SAP systems. This error typically arises when the system encounters an invalid value for this switch, which is used to control the monitoring of database tables.
Cause: Invalid Configuration: The DFT_MON_TABLE switch may have been set to an invalid value, which could be due to manual changes or incorrect configuration during system setup or updates. Database Issues: There may be underlying issues with the database itself that are causing the monitoring parameters to be misconfigured. SAP Notes: Sometimes, specific SAP Notes or patches may not have been applied, leading to inconsistencies in system behavior.
Solution: Check Configuration: Verify the configuration of the DFT_MON_TABLE switch. You can do this by accessing the relevant database configuration settings in the SAP system. Ensure that the value set for this switch is valid and corresponds to the expected
Get instant SAP help. Sign up for our Free Essentials Plan.
DB6529
The DFT_MON_TABLE switch is not set
Copy of DB6 527What causes this issue? To allow meaningful monitoring of the database, you must activate this switch.System Response If this switch...
DB6528
The DFT_MON_TABLE switch is set
INCLUDE BC_DB6_OK OBJECT DOKU ID TX LANGUAGE ENError message extract from SAP system. Copyright SAP SE. ...
DB6531
Monitoring of the UOWs (Unit of Work)
Copy of DB6 511 except for user entryWhat causes this issue? To allow meaningful monitoring of the database, you must activate this switch.System Re...
DB6532
The DFT_MON_UOW switch is set
INCLUDE BC_DB6_OK OBJECT DOKU ID TX LANGUAGE ENError message extract from SAP system. Copyright SAP SE. ...
Click on this link to search all SAP messages.