Message type: E = Error
Message class: DB6 - DB6: Alert Monitoring and Alert Configuration
Message number: 522
Message text: An invalid value has been returned for the DFT_MON_SORT switch
To allow meaningful monitoring of the database, you must activate this
switch.
If this switch is not set, it can lead to problems ranging from
restricting the function of the CCMS transactions to erroneous
terminations.
Activate the switch by setting the appropriate database manager
parameters using the following command:
<LB>UPDATE DBM CFG USING DFT_MON_SORT ON </>
The setting will become active at the next connection to the database.
Error message extract from SAP system. Copyright SAP SE.
DB6522
- An invalid value has been returned for the DFT_MON_SORT switch ?The SAP error message DB6522, which states "An invalid value has been returned for the DFT_MON_SORT switch," typically relates to issues with database monitoring settings in the SAP system. This error can occur when the system is trying to access or utilize a database monitoring feature, but the configuration for the DFT_MON_SORT switch is not set correctly.
Cause: Invalid Configuration: The DFT_MON_SORT switch may have been set to an invalid value in the database configuration. Database Compatibility: The error may arise if there is a mismatch between the SAP system version and the database version or if the database is not properly configured to work with the SAP system. Corrupted Parameters: Sometimes, parameters in the database configuration can become corrupted or misconfigured, leading to this error.
Solution: Check Configuration: Access the database configuration settings and verify the value of the DFT_MON_SORT switch. Ensure it is set to a valid value as per the database documentation. The valid
Get instant SAP help. Sign up for our Free Essentials Plan.
DB6521
The DFT_MON_SORT switch is not set
Copy of DB6 519What causes this issue? To allow meaningful monitoring of the database, you must activate this switch.System Response If this switch...
DB6520
The DFT_MON_SORT switch is set
INCLUDE BC_DB6_OK OBJECT DOKU ID TX LANGUAGE ENError message extract from SAP system. Copyright SAP SE. ...
DB6523
Statement cache monitoring
Copy of DB6 511 except for user entryWhat causes this issue? To allow meaningful monitoring of the database, you must activate this switch.System Re...
DB6524
The DFT_MON_STMT switch is set
INCLUDE BC_DB6_OK OBJECT DOKU ID TX LANGUAGE ENError message extract from SAP system. Copyright SAP SE. ...
Click on this link to search all SAP messages.