Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: DA - Dictionary: Compare, distribution, timer, instantiation
Message number: 161
Message text: Row &1: Unknown control structure '&2'
The specified type of control structure is unknown.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Choose a control structure type:
C : Conditionals
T : Table Loop
F : Function Loop
S : Subscheme Call
You can find a description of the control structures in the
documentation for the function module SCHEME_INSTANTIATE.
Error message extract from SAP system. Copyright SAP SE.
DA161
- Row &1: Unknown control structure '&2' ?The SAP error message DA161, which states "Row &1: Unknown control structure '&2'", typically occurs in the context of data processing or data extraction, particularly when working with data sources or data models in SAP BW (Business Warehouse) or similar environments. This error indicates that the system has encountered a control structure (like a data field or a key figure) that it does not recognize or cannot find in the specified row.
Causes:
- Missing Control Structure: The control structure referenced in the error message may not exist in the data model or InfoProvider.
- Incorrect Configuration: There may be a misconfiguration in the data source or transformation rules that reference the control structure.
- Data Model Changes: If there have been recent changes to the data model (like adding or removing fields), the control structure may have been inadvertently removed or renamed.
- Transport Issues: If the data model was transported from one system to another, there may have been issues during the transport that caused the control structure to be missing.
- Version Mismatch: The version of the data source or InfoProvider may not match the version expected by the data extraction process.
Solutions:
- Check Control Structure: Verify that the control structure '&2' exists in the data model. You can do this by checking the relevant InfoObject or InfoProvider in the SAP BW system.
- Review Configuration: Go through the configuration of the data source and transformation rules to ensure that they are correctly set up and that all necessary fields are included.
- Recreate Control Structure: If the control structure is missing, you may need to recreate it or restore it from a backup if it was deleted.
- Transport Validation: If the issue arose after a transport, check the transport logs for errors and ensure that all necessary objects were transported correctly.
- Update Data Model: If there have been changes to the data model, ensure that all dependent objects are updated accordingly.
- Consult Documentation: Refer to SAP documentation or notes related to the specific version of the software you are using for any known issues or patches.
Related Information:
If the problem persists after trying the above solutions, it may be beneficial to reach out to SAP support or consult with a technical expert who specializes in SAP BW or the specific module you are working with.
Get instant SAP help. Sign up for our Free Essentials Plan.
DA160
Row &1: Schema &2 not correctly concluded with &3
What causes this issue? Another scheme was started before the last one was ended.System Response The system issues an error message and will not all...
DA159
******** New Schema Instantiator (FM) **********
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DA162
Row &1: Unbalanced variable delimiter '&2' for &3
What causes this issue? A variable delimitor '&' is missing.System Response The system issues an error message and will not allow you ...
DA163
Row &1: Control structure '&2 &3' does not have enough parts
What causes this issue? Not enough parts were specified within a control structure.System Response The system issues an error message and will not a...
Click on this link to search all SAP messages.