Do you have any question about this error?
Message type: E = Error
Message class: DA - Dictionary: Compare, distribution, timer, instantiation
Message number: 103
Message text: Control structure not concluded with &
The subscheme was not concluded.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Conclude the subscheme with '$/'.
Error message extract from SAP system. Copyright SAP SE.
DA103
- Control structure not concluded with & ?The SAP error message DA103, which states "Control structure not concluded with &," typically occurs in the context of ABAP programming. This error indicates that there is an issue with the control structure in your code, specifically that a control structure (like a loop or conditional statement) is not properly concluded.
Cause:
The error is usually caused by one of the following:
- Incomplete Control Structure: You have started a control structure (like
IF
,CASE
,LOOP
, etc.) but have not properly closed it with the correspondingENDIF
,ENDCASE
, orENDLOOP
.- Incorrect Syntax: There may be a syntax error in the control structure that prevents it from being recognized as complete.
- Missing or Extra Characters: Sometimes, missing or extra characters (like a missing
&
in a string concatenation) can lead to this error.Solution:
To resolve the DA103 error, follow these steps:
Check Control Structures: Review your code for any control structures that are not properly closed. Ensure that every
IF
has a correspondingENDIF
, everyLOOP
has anENDLOOP
, and everyCASE
has anENDCASE
.Example:
IF condition. " some code ENDIF. " Ensure this is present
Review Syntax: Make sure that the syntax of your control structures is correct. Look for any misplaced or missing keywords.
Look for Concatenation Issues: If you are using string concatenation, ensure that you are using the
&
operator correctly. For example:DATA(result) = 'Hello' && ' World'. " Correct usage
Use Syntax Check: Use the syntax check feature in the ABAP editor (transaction SE38 or SE80) to identify any syntax errors in your code.
Debugging: If the error persists, consider debugging the program to see where the control structure is being incorrectly interpreted.
Related Information:
By following these steps, you should be able to identify and fix the cause of the DA103 error in your ABAP code.
Get instant SAP help. Start your 7-day free trial now.
DA102
Schema &1 does not exist in program &2
What causes this issue? A scheme was to be instantiated which is not defined in the program.System Response The system issues an error message and w...
DA101
Schema program &1 does not exist
What causes this issue? A scheme was to be instantiated in a program which does not exist.System Response The system issues an error message and wil...
DA104
Two variables delimiters & in sequence in &
What causes this issue? No variable name falls within the variable delimiters.System Response The system issues an error message and will not allow ...
DA105
Variable & not bound in &
What causes this issue? The scheme contains a variable which is not globally declared in the program in which the scheme instantiator is called.Syste...
Click on this link to search all SAP messages.