Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: DA - Dictionary: Compare, distribution, timer, instantiation
Message number: 103
Message text: Control structure not concluded with &
The subscheme was not concluded.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Conclude the subscheme with '$/'.
Error message extract from SAP system. Copyright SAP SE.
DA103
- Control structure not concluded with & ?The SAP error message DA103, which states "Control structure not concluded with &," typically occurs in the context of ABAP programming. This error indicates that there is an issue with the control structure in your code, specifically that a control structure (like a loop or conditional statement) is not properly concluded.
Cause:
The error is usually caused by one of the following:
- Incomplete Control Structure: You have started a control structure (like
IF
,CASE
,LOOP
, etc.) but have not properly closed it with the correspondingENDIF
,ENDCASE
, orENDLOOP
.- Incorrect Syntax: There may be a syntax error in the control structure that prevents it from being recognized as complete.
- Missing or Extra Characters: Sometimes, missing or extra characters (like a missing
&
in a string concatenation) can lead to this error.Solution:
To resolve the DA103 error, follow these steps:
Check Control Structures: Review your code for any control structures that are not properly closed. Ensure that every
IF
has a correspondingENDIF
, everyLOOP
has anENDLOOP
, and everyCASE
has anENDCASE
.Example:
IF condition. " some code ENDIF. " Ensure this is present
Review Syntax: Make sure that the syntax of your control structures is correct. Look for any misplaced or missing keywords.
Look for Concatenation Issues: If you are using string concatenation, ensure that you are using the
&
operator correctly. For example:DATA(result) = 'Hello' && ' World'. " Correct usage
Use Syntax Check: Use the syntax check feature in the ABAP editor (transaction SE38 or SE80) to identify any syntax errors in your code.
Debugging: If the error persists, consider debugging the program to see where the control structure is being incorrectly interpreted.
Related Information:
By following these steps, you should be able to identify and fix the cause of the DA103 error in your ABAP code.
Get instant SAP help. Sign up for our Free Essentials Plan.
DA102
Schema &1 does not exist in program &2
What causes this issue? A scheme was to be instantiated which is not defined in the program.System Response The system issues an error message and w...
DA101
Schema program &1 does not exist
What causes this issue? A scheme was to be instantiated in a program which does not exist.System Response The system issues an error message and wil...
DA104
Two variables delimiters & in sequence in &
What causes this issue? No variable name falls within the variable delimiters.System Response The system issues an error message and will not allow ...
DA105
Variable & not bound in &
What causes this issue? The scheme contains a variable which is not globally declared in the program in which the scheme instantiator is called.Syste...
Click on this link to search all SAP messages.