Do you have any question about this error?
Message type: E = Error
Message class: CUMTX - Variant Configuration - Master Data Maintenance
Message number: 692
Message text: New engineering change management is not yet released for variant tables
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
CUMTX692
- New engineering change management is not yet released for variant tables ?The SAP error message CUMTX692, which states "New engineering change management is not yet released for variant tables," typically occurs in the context of using the Engineering Change Management (ECM) functionality in SAP, particularly when dealing with variant configuration.
Cause:
This error usually arises when:
- Engineering Change Management (ECM) is not activated: The ECM functionality may not be fully configured or activated in your SAP system.
- Variant Table Not Released: The specific variant table you are trying to work with has not been released for use in the engineering change management process.
- Configuration Issues: There may be issues with the configuration settings related to the variant table or the ECM settings.
Solution:
To resolve this error, you can take the following steps:
Check ECM Activation:
- Ensure that the Engineering Change Management functionality is activated in your SAP system. This can typically be done through transaction codes like
SPRO
(SAP Project Reference Object) to access the configuration settings.Release the Variant Table:
- Navigate to the relevant variant table in the system and check its status. If it is not released, you will need to release it. This can usually be done through the transaction code
C223
(Change Variant Table) orC222
(Display Variant Table).- Ensure that the variant table is properly configured and released for use in the ECM process.
Check Configuration Settings:
- Review the configuration settings related to the variant table and ECM. Ensure that all necessary settings are correctly defined and that there are no missing configurations.
Consult Documentation:
- Refer to SAP documentation or help resources for detailed guidance on ECM and variant tables. This can provide insights into specific configuration steps or requirements.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They can provide more specific guidance based on your system configuration and version.
Related Information:
C223
, C222
, and SPRO
for configuration and management of variant tables and ECM.By following these steps, you should be able to address the CUMTX692 error and ensure that your variant tables are properly set up for use with Engineering Change Management in SAP.
Get instant SAP help. Start your 7-day free trial now.
CUMTX691
Use transaction & to maintain planning tables
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CUMTX690
Use transaction & to maintain variant tables
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CUMTX693
Please use transaction &1 to maintain AVC variant tables.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CUMTX896
Processing of &1 &2 &3 terminated due to error
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.