Do you have any question about this error?
Message type: E = Error
Message class: CU - Variants / configuration messages
Message number: 878
Message text: Configuration structure screen not allowed for confign browser setting
The <ZH>Confign structure</> screen is no longer required if you select
the configuration browser, because the configuration browser shows the
structure.
Error message extract from SAP system. Copyright SAP SE.
CU878
- Configuration structure screen not allowed for confign browser setting ?The SAP error message CU878, which states "Configuration structure screen not allowed for config browser setting," typically occurs in the context of using the Configuration Browser in SAP, particularly when dealing with configurable materials in the SAP Variant Configuration (VC) module.
Cause:
The error is generally caused by one of the following reasons:
Configuration Profile Settings: The configuration profile for the material may not be set up to allow the use of the configuration browser. This can happen if the settings in the configuration profile do not permit the display of the configuration structure.
User Authorizations: The user may not have the necessary authorizations to access the configuration structure screen.
Incorrect Configuration: The configuration settings for the material or the class may not be correctly defined, leading to restrictions on how the configuration can be displayed or modified.
Browser Settings: The configuration browser settings may not be properly configured to allow the display of the configuration structure.
Solution:
To resolve the CU878 error, you can take the following steps:
Check Configuration Profile:
- Go to the configuration profile of the material in question (transaction code CU41 or CU42).
- Ensure that the settings allow for the configuration structure to be displayed. Look for options related to the configuration browser and ensure they are enabled.
Review User Authorizations:
- Check the user roles and authorizations to ensure that the user has the necessary permissions to access the configuration structure. This may involve working with your SAP security team to verify and adjust roles as needed.
Validate Configuration Settings:
- Review the configuration settings for the material and the associated class. Ensure that all necessary characteristics and dependencies are correctly defined.
Adjust Configuration Browser Settings:
- If applicable, check the settings for the configuration browser itself. This may involve transaction codes like CU00 or other related settings to ensure that the browser is configured to allow the display of the configuration structure.
Consult Documentation:
- Refer to SAP documentation or help resources for additional guidance on configuration profiles and browser settings.
SAP Notes:
- Check for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
Related Information:
By following these steps, you should be able to identify the root cause of the CU878 error and implement the necessary changes to resolve it.
Get instant SAP help. Start your 7-day free trial now.
CU875
Status & not defined for configuration profiles for object &
What causes this issue? Status &v1& is not defined for configuration profiles for object &v2&.System Response The system checks the ...
CU874
Alternative language not defined
What causes this issue? The language key you entered for the alternative language is not defined in your system.System Response The system checks wh...
CU882
Configuration structure not allowed, because "Confign browser" is set
What causes this issue? You cannot use or start configuration with the <ZH>Configuration structure</> screen if you set the <ZH>Con...
CU884
Error checking or deleting interface design
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.