Do you have any question about this error?
Message type: E = Error
Message class: CRD_TEST_FRAMEWORK - Credentialing: Test Framework
Message number: 024
Message text: Generating a data reference of type &1 failed
A data reference of the type &v1& (structure) is supposed to be
generated at runtime. However the structure may <ZH>not</> have been
created in the ABAP Dictionary.
The exception CX_SY_CREATE_DATA_ERROR was triggered at runtime with the
following short text: <ZK>&v2&</>
If the missing structure is a generated structure, make sure that the
application has been completely generated without errors. You can
recognize generated datatypes by the first part of the application.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CRD_TEST_FRAMEWORK024
- Generating a data reference of type &1 failed ?The SAP error message CRD_TEST_FRAMEWORK024 indicates that there was a failure in generating a data reference of a specific type during the execution of a test framework or related process. This error typically arises in the context of ABAP development, particularly when working with data references or dynamic programming.
Cause:
The error can be caused by several factors, including:
- Invalid Data Type: The specified data type (&1) may not be valid or recognized in the context where it is being used.
- Type Mismatch: There may be a mismatch between the expected data type and the actual data type being referenced.
- Uninitialized Variables: The variable or object being referenced may not have been properly initialized before the reference was attempted.
- Incorrect Syntax: There may be a syntax error in the code that is attempting to generate the data reference.
- Access Issues: There could be issues related to access permissions or visibility of the data type in the current context.
Solution:
To resolve the error, you can take the following steps:
- Check Data Type: Verify that the data type specified in the error message is correct and valid. Ensure that it is defined in the system and accessible in the current context.
- Review Code: Look at the code where the error occurs. Check for any syntax errors or logical issues that might lead to the failure in generating the data reference.
- Initialization: Ensure that all variables and objects are properly initialized before they are used. This includes checking for null references or uninitialized structures.
- Debugging: Use the ABAP debugger to step through the code and identify the exact point of failure. This can provide insights into what is going wrong.
- Consult Documentation: Refer to SAP documentation or help resources for more information on the specific data type and its usage.
- Check Authorizations: Ensure that you have the necessary authorizations to access the data type or object in question.
Related Information:
If the issue persists after following these steps, consider reaching out to SAP support for further assistance, providing them with detailed information about the error and the context in which it occurs.
Get instant SAP help. Start your 7-day free trial now.
CRD_TEST_FRAMEWORK023
Generating a structure during runtime failed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CRD_TEST_FRAMEWORK022
Structure &1 does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CRD_TEST_FRAMEWORK025
Cannot generate instance for class &1
What causes this issue? The system is trying to generate an instance for class &v1&. A prerequisite of this is that class &v1& imple...
CRD_TEST_FRAMEWORK026
Cannot display selection list of transaction data
What causes this issue? A selection list for the transaction data should be displayed. However this is not possible due to the following error:&v...
Click on this link to search all SAP messages.