Message type: E = Error
Message class: CPOC2 - PP-PI-PMA: PI Sheet Messages, SCM Add-On
Message number: 142
Message text: Function module &1: The formal parameter &2 has not been typed
A dynamic function call is defined in the process instruction. The
formal parameter &V2& in function module &V1& has not been typed.
This may mean that the function call cannot be correctly executed, or
the program might terminate.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check in the <DS:TRAN.SE37>Function Builder</> whether the formal
parameter &V2& in function module &V1& is typed correctly.
Enter a valid type for formal parameter &V2&.
Error message extract from SAP system. Copyright SAP SE.
CPOC2142
- Function module &1: The formal parameter &2 has not been typed ?The SAP error message CPOC2142 indicates that there is an issue with a function module where a formal parameter has not been properly typed. This typically occurs during the execution of a function module in ABAP (Advanced Business Application Programming) when the system encounters a parameter that lacks a defined data type.
Cause: Missing Data Type: The formal parameter in the function module is not defined with a data type. This can happen if the function module was created or modified incorrectly. Inconsistent Definitions: If the function module is being called with parameters that do not match the expected types, it can lead to this error. Transport Issues: If the function module was transported from one system to another, there might be inconsistencies in the definitions due to missing or incomplete transport requests.
Solution: Check Function Module Definition: Go to transaction SE37 (Function Builder) and enter the name of the function module indicated in the error message. Check
Get instant SAP help. Sign up for our Free Essentials Plan.
CPOC2141
No process instructions or process instruction characteristics exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CPOC2113
External data point &1 not active
What causes this issue? A data access (PPPI_DATA_ACCESS) to an external data point is defined in the process instruction. However, the data point spe...
CPOC2143
Constant &1 cannot be transferred to import parameter &2
What causes this issue? A dynamic function call is defined in the process instruction. The reference type of import parameter &v2& is a table...
CPOC2144
Do not set variable &1 as the input value with PPPI_DEFAULT_VARIABLE
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.