How To Fix CPOC2030 - System error during optical archiving (See long text)


CPOC2030 - Overview

  • Message type: E = Error

  • Message class: CPOC2 - PP-PI-PMA: PI Sheet Messages, SCM Add-On

  • Message number: 030

  • Message text: System error during optical archiving (See long text)

  • Show details Hide details
  • What causes this issue?

    An error has occurred during the optical archiving of the PI sheet/work
    instructions &V1&.

    System Response

    Archiving has been terminated.

    How to fix this error?

    Contact your system administrator.

    Procedure for System Administrators

    Check the ArchiveLink Customizing settings for the <LS>object type</>
    <LB>BUS4200000</> for the <LS>document type</> <LB>PROD_INST</>
    (transaction <DS><DS:TRAN.OAC2>OAC2</></>) and for the HTTP content
    server on which the PI sheet/set of work instructions is to be stored
    (transaction <DS><DS:TRAN.OAC0>OAC0</></>).
    Check that an active ArchiveLink linkage exists for the a.m. <LS>object
    type</> and the <LS>document type</> for the <LS>linkage table</> TOA01
    (transaction <DS><DS:TRAN.OAC3>OAC3</></>).

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message CPOC2030 - System error during optical archiving (See long text) ?
    The SAP error message CPOC2030 indicates a system error that occurred during the optical archiving process. This error can arise from various underlying issues, and the long text of the error message typically provides more specific details about the nature of the problem. Here are some common causes, potential solutions, and related information for this error:
    Causes:
    
    
    Configuration Issues: Incorrect configuration settings in the optical archiving setup can lead to errors. Network Problems: Connectivity issues between the SAP system and the optical archiving device or server. File System Errors: Problems with the file system where the archived documents are stored, such as insufficient space or permission issues. Software Bugs: Bugs in the SAP software or the optical archiving interface can cause unexpected errors. Database Issues: Problems with the database that stores metadata related to the archived documents. Solutions: Check Configuration: Review the configuration settings for optical archiving in the SAP system. Ensure that all parameters are correctly set

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author