Do you have any question about this error?
Message type: E = Error
Message class: CPE_IPC - CPE: Message Class for Pricing Engine Part
Message number: 550
Message text: Invalid CPE quantity split routine &2
An error occurred with the commodity pricing engine (CPE) during FA
procedure determination, formula assembly, formula evaluation, or
formula analysis.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Contact your system administrator.
The error occurred with the following object:
Pricing Condition Type: &V1&
Quantity Split Routine: &V2&
Error message extract from SAP system. Copyright SAP SE.
CPE_IPC550
- Invalid CPE quantity split routine &2 ?The SAP error message CPE_IPC550 "Invalid CPE quantity split routine &2" typically occurs in the context of the SAP Advanced Planning and Optimization (APO) module, particularly when dealing with the Collaborative Planning Environment (CPE). This error indicates that there is an issue with the quantity split routine that is being used in the planning process.
Cause:
- Invalid Routine Configuration: The error often arises when the quantity split routine specified in the planning book or data view is not correctly configured or does not exist in the system.
- Missing or Incorrect Parameters: The routine may be missing required parameters or may have been incorrectly defined, leading to the system being unable to execute it properly.
- Data Inconsistencies: There may be inconsistencies in the data being processed, such as incorrect or missing entries in the master data or transaction data that the routine relies on.
Solution:
Check Routine Configuration:
- Go to the configuration settings for the quantity split routine in the SAP system.
- Verify that the routine specified (denoted by &2 in the error message) exists and is correctly configured.
- Ensure that all necessary parameters for the routine are defined and valid.
Review Planning Book Settings:
- Check the planning book or data view settings where the routine is being used.
- Ensure that the correct routine is assigned and that it matches the intended use case.
Validate Master Data:
- Review the master data related to the planning process, such as product master, location master, and any other relevant data.
- Ensure that all required data is present and correctly maintained.
Test the Routine:
- If possible, test the quantity split routine in a controlled environment to see if it executes without errors.
- This can help identify if the issue is with the routine itself or with the data being processed.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific routine and its expected configuration.
- Check for any known issues or updates that may address the error.
Seek Support:
- If the issue persists, consider reaching out to SAP support or consulting with a technical expert who specializes in SAP APO and CPE.
Related Information:
/SAPAPO/SDP94
(for planning book) or /SAPAPO/MC62
(for configuration) to access relevant settings.By following these steps, you should be able to identify and resolve the cause of the CPE_IPC550 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
CPE_IPC549
Invalid CPE term type routine &2
What causes this issue? An error occurred with the commodity pricing engine (CPE) during FA procedure determination, formula assembly, formula evalua...
CPE_IPC548
Invalid CPE combination routine &2
What causes this issue? An error occurred with the commodity pricing engine (CPE) during FA procedure determination, formula assembly, formula evalua...
CPE_IPC551
No terms found for CPE formula &2
What causes this issue? An error occurred with the commodity pricing engine (CPE) during FA procedure determination, formula assembly, formula evalua...
CPE_IPC552
All CPE terms contain errors
What causes this issue? An error occurred with the commodity pricing engine (CPE) during FA procedure determination, formula assembly, formula evalua...
Click on this link to search all SAP messages.