Do you have any question about this error?
Message type: E = Error
Message class: COOPC - Messages for SAP-OPC Integration
Message number: 402
Message text: Error while writing OPC item &1; see long text
The system tried to write a value to the OPC item &V1& that is defined
in plant &V2&. However, an internal error occurred that cannot be
specified any further.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
You can try to correct the error by carrying out the following steps:
Test the connection to the RFC destination &V2& in Customizing.
To do so, go to Customizing for <LS>Production Planning - Process
Industries</> and choose <LS>Process Management</> -> <LS>SAP ODA (OPC
Data Access)</> -> <DS:SIMG.COOPC120>Define Settings for SAP ODA</>.
Try to access the OPC server via any
<DS:GLOS.34FECE44B0CAD411B11B0008C784EFB1>OPC client</> from another
vendor.
If this is possible, there is probably an program error in the SAP
system. Contact SAP.
If this is not possible, there is probably an error on the OPC server.
Contact the OPC server vendor.
Error message extract from SAP system. Copyright SAP SE.
COOPC402
- Error while writing OPC item &1; see long text ?The SAP error message COOPC402 typically indicates an issue related to the OPC (OLE for Process Control) interface when trying to write to an OPC item. This error can occur in various scenarios, often related to configuration or communication issues between SAP and the OPC server.
Cause:
- Configuration Issues: The OPC item may not be correctly configured in the SAP system or the OPC server.
- Network Issues: There may be network connectivity problems between the SAP system and the OPC server.
- Permissions: The user or service account may not have the necessary permissions to write to the OPC item.
- Item Availability: The OPC item may not be available or may not exist in the OPC server.
- Data Type Mismatch: There may be a mismatch between the data type expected by the OPC item and the data being sent from SAP.
Solution:
- Check Configuration: Verify the configuration of the OPC item in both SAP and the OPC server. Ensure that the item name and parameters are correctly set.
- Test Connectivity: Use tools to test the network connection between the SAP system and the OPC server. Ensure that the OPC server is running and accessible.
- Review Permissions: Check the permissions for the user or service account that is attempting to write to the OPC item. Ensure it has the necessary rights.
- Validate OPC Item: Confirm that the OPC item exists and is available on the OPC server. You can use an OPC client tool to browse the items on the server.
- Check Data Types: Ensure that the data being sent from SAP matches the expected data type of the OPC item. If there is a mismatch, adjust the data accordingly.
Related Information:
If the problem persists after trying the above solutions, it may be beneficial to engage with SAP support or your system administrator for further assistance.
Get instant SAP help. Start your 7-day free trial now.
COOPC401
Error while reading OPC item &1; see long text
What causes this issue? The system tried to read the current value of the <DS:GLOS.D39F4241B0CAD411B11B0008C784EFB1>OPC item</> &V1&a...
COOPC400
;;--------OPC DA-Specific Messages------------------------------
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
COOPC403
First deactivate the current OPC Data Access subscription
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
COOPC500
;;--------OPC A/E-Specific Messages--------------------------------------
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.