Do you have any question about this error?
Message type: E = Error
Message class: CONNECT_PRC_SAPCND -
Message number: 007
Message text: Unit of measure &1 (for product) unknown.
Unit of measure &v1& for data element &v2& is not yet defined in
product master.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Leave unit of measure empty and copy proposal or use F4 help. If no
unit of measure has been accepted without errors, no unit of measure is
maintained in the product master or there is none in the buffer.
Save the transaction and save the automatic proposal.
Error message extract from SAP system. Copyright SAP SE.
CONNECT_PRC_SAPCND007
- Unit of measure &1 (for product) unknown. ?The SAP error message
CONNECT_PRC_SAPCND007
indicates that there is an issue with the unit of measure (UoM) for a specific product in the system. This error typically arises when the system cannot find the specified unit of measure for the product in question, which can lead to issues in processing transactions or data related to that product.Cause:
- Missing Unit of Measure: The specified unit of measure for the product is not defined in the system.
- Incorrect Configuration: The product may be configured incorrectly, leading to a mismatch between the expected and actual units of measure.
- Data Inconsistency: There may be inconsistencies in the master data, such as the material master or product master, where the unit of measure is not properly maintained.
- Transport Issues: If the product or its unit of measure was recently transported from another system, it may not have been set up correctly in the target system.
Solution:
- Check Material Master: Go to the material master (transaction code
MM03
) and verify that the unit of measure is correctly defined for the product. Ensure that the UoM is active and properly maintained.- Maintain Unit of Measure: If the unit of measure is missing, you can add it using transaction code
MM02
to modify the material master and include the necessary UoM.- Review Configuration: Check the configuration settings in the relevant modules (like MM, SD, or PP) to ensure that the unit of measure settings are correct.
- Data Consistency Check: Run data consistency checks to identify any discrepancies in the master data that may be causing the issue.
- Transport Request: If the issue arose after a transport, ensure that all necessary objects related to the product and its unit of measure were included in the transport request.
Related Information:
T006
(Units of Measure)T006A
(Units of Measure: Language-dependent Texts)MM03
: Display MaterialMM02
: Change MaterialMM01
: Create MaterialIf the problem persists after following these steps, it may be beneficial to consult with your SAP support team or refer to SAP documentation for further troubleshooting.
Get instant SAP help. Start your 7-day free trial now.
CONNECT_PRC_SAPCND006
Unit of measure &1 cannot be checked.
What causes this issue? Unit of measure &V1& could not be checked because the relevant product is not known, has not yet been made, has not y...
CONNECT_PRC_SAPCND005
Unit of measure for calculation type &1 must be completed.
What causes this issue? The quantity unit of measure together with the calculation type &v1& is an obligatory field.System Response The syst...
CONNECT_PRC_SAPCND008
Unit of measure &1 not known.
What causes this issue? Unit of measure not yet known.System Response The system issues an error message and will not allow you to continue with thi...
CONNECT_PRC_SAPCND009
Unit of measure &1 is not a base unit of measure or order unit.
What causes this issue? The unit of measure entered is not the order unit or the base unit of measure for the product.System Response The system iss...
Click on this link to search all SAP messages.