Message type: E = Error
Message class: CNVMBTRFC - Messages used in RFC Management and its objects
Message number: 080
Message text: Process type does not exist in table cnvmbtproctype
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
CNVMBTRFC080
- Process type does not exist in table cnvmbtproctype ?The SAP error message CNVMBTRFC080 indicates that a specific process type does not exist in the table cnvmbtproctype. This error typically arises during data migration or conversion processes, particularly when using the SAP Migration Cockpit or other data migration tools.
Cause: Missing Process Type: The process type you are trying to use is not defined in the cnvmbtproctype table. This could happen if the migration project was not set up correctly or if the necessary configuration was not completed. Incorrect Configuration: The migration project may have been configured incorrectly, leading to references to non-existent process types. Transport Issues: If the relevant configuration was transported from another system, it may not have been included or may have been incorrectly transported.
Solution: Check Configuration: Verify that the process type you are trying to use is correctly defined in the cnvmbtproctype table. You can do this by executing a SQL query or using transaction SE11 to view the table. Define
Get instant SAP help. Sign up for our Free Essentials Plan.
CNVMBTRFC079
Control System must be the local system. Check destination &1.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVMBTRFC078
Special settings with different execution targets.
What causes this issue? The special settings and the distributed destination was compared and it was found that the receiving and distributed executi...
CNVMBTRFC081
No entry exist in table cnvmbtdest for packid &1 and execution target &2.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVMBTRFC082
Not allowed to use destination NONE for the execution target &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.