Do you have any question about this error?
Message type: E = Error
Message class: CNVMBTRFC - Messages used in RFC Management and its objects
Message number: 026
Message text: Subproject &1 with destination &2 address two different control systems.
Cause of the error
The synchronization check finds out that there is a conflict with
another control system. The error message give the information which
subproject and destination is affected. In the detaild status you also
get the information which destination is affected.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The check found out that in the system/client where we wanted toError message extract from SAP system. Copyright SAP SE.
CNVMBTRFC026
- Subproject &1 with destination &2 address two different control systems. ?The SAP error message CNVMBTRFC026 typically occurs in the context of a data migration or conversion process, particularly when using the SAP Landscape Transformation (SLT) or similar tools. This error indicates that a subproject is trying to address two different control systems, which can lead to inconsistencies or conflicts in data processing.
Cause:
The error arises when:
- Configuration Issues: The subproject is incorrectly configured to point to multiple control systems, which can happen if the destination settings are not properly defined.
- Data Consistency: The system detects that the same subproject is attempting to interact with two different control systems, which can lead to data integrity issues.
- Transport Layer Issues: There may be issues with the transport layer or RFC (Remote Function Call) connections that are not set up correctly.
Solution:
To resolve the CNVMBTRFC026 error, you can take the following steps:
Check Configuration:
- Review the configuration of the subproject in the SAP system. Ensure that it is set up to point to only one control system.
- Verify the destination settings in transaction SM59 (RFC Destinations) to ensure that the correct control system is being referenced.
Review Subproject Settings:
- Go to the relevant transaction or tool used for the migration (e.g., transaction CNV_MBT).
- Check the settings for the subproject and ensure that it is not inadvertently configured to connect to multiple control systems.
Correct RFC Connections:
- Ensure that the RFC connections are correctly defined and that there are no duplicate or conflicting entries.
- Test the RFC connections to ensure they are functioning correctly.
Consult Documentation:
- Refer to the SAP documentation or notes related to the specific migration tool you are using. There may be specific guidelines or known issues that can provide further insight.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP Support for assistance. Provide them with the error message details and any relevant logs or configuration settings.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the CNVMBTRFC026 error in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
CNVMBTRFC025
Not possible to run search for system id and activated check box
What causes this issue? The function module for searching for RFC destinations was called with a value in field 'System Id' and the activat...
CNVMBTRFC024
No line selected. Make your selection.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVMBTRFC027
Function module &1 has finished with return code &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVMBTRFC028
Parameter table &1 from fumo &2 does not have any entries.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.