Do you have any question about this error?
Message type: E = Error
Message class: CNV_PE - General messages for posting engine
Message number: 504
Message text: Data model table &1 is already connected to embedded specification
Data model table &V1& is already connected to embedded specification.
Position of data model in embedded specification: &V2&
Table ID: &V3&
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CNV_PE504
- Data model table &1 is already connected to embedded specification ?The SAP error message CNV_PE504 indicates that a data model table is already connected to an embedded specification. This typically occurs during data migration or transformation processes, particularly when using SAP's Conversion Tools or Data Migration tools.
Cause:
The error arises when you attempt to connect a data model table to an embedded specification that is already linked to another table or specification. This can happen due to:
- Duplicate Connections: The same table is being referenced multiple times in the data model.
- Incorrect Configuration: The configuration of the data model may not be set up correctly, leading to conflicts in table connections.
- Data Model Design Issues: The design of the data model may not adhere to the expected structure, causing conflicts when trying to establish connections.
Solution:
To resolve the CNV_PE504 error, you can follow these steps:
Check Existing Connections:
- Review the data model to identify which tables are already connected to the embedded specification.
- Ensure that the table you are trying to connect is not already linked to another specification.
Modify Connections:
- If the table is already connected, consider whether you can modify the existing connection instead of creating a new one.
- If necessary, disconnect the existing connection before attempting to connect the table to the new specification.
Review Data Model Design:
- Ensure that the data model is designed correctly and adheres to the expected structure.
- Make adjustments to the model to avoid conflicts in table connections.
Consult Documentation:
- Refer to SAP documentation or guides related to the specific data migration or conversion tool you are using for additional insights and best practices.
Seek Support:
- If the issue persists, consider reaching out to SAP support or consulting with a technical expert who specializes in SAP data migration.
Related Information:
By following these steps, you should be able to resolve the CNV_PE504 error and successfully connect your data model tables as needed.
Get instant SAP help. Start your 7-day free trial now.
CNV_PE503
Embedded specification position for data model table &1 is not provided
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_PE502
Undo transfer method &1 is assigned to multiple transfer methods
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_PE505
Area is assigned to embedded specification; deletion impossible
What causes this issue? Area <ZH>&V1&</> is still assigned to an embedded specification, which means that the deletion of the are...
CNV_PE506
Link to BO data model for table &1 is not provided
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.