Do you have any question about this error?
Message type: E = Error
Message class: CNV_PE - General messages for posting engine
Message number: 179
Message text: Parameter &1 is activated
Parameter with name &V1& and ID &V2& was activated.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CNV_PE179
- Parameter &1 is activated ?The SAP error message CNV_PE179, which states "Parameter &1 is activated," typically occurs in the context of data migration or conversion processes, particularly when using the SAP S/4HANA Migration Cockpit or other data migration tools. This error indicates that a specific parameter (denoted by &1) is activated in the system, which may not be compatible with the current operation or migration process.
Cause:
The error is usually caused by one of the following reasons:
- Incompatible Configuration: The parameter that is activated may not be suitable for the data migration process you are attempting to execute.
- System Settings: Certain system settings or configurations may need to be adjusted to allow for the migration or conversion to proceed without issues.
- Data Migration Tool Limitations: The data migration tool being used may have specific requirements or limitations regarding activated parameters.
Solution:
To resolve the CNV_PE179 error, you can take the following steps:
Identify the Parameter: Check the specific parameter that is indicated by &1 in the error message. You can usually find this in the detailed error log or message details.
Review Documentation: Consult the SAP documentation or notes related to the specific migration or conversion process you are performing. This may provide insights into the implications of the activated parameter.
Adjust System Settings:
- If the parameter is not required for your migration process, consider deactivating it. This can typically be done through transaction codes like
RZ10
(for profile parameters) orSPRO
(for configuration settings).- If the parameter is necessary for other processes, you may need to find a workaround or alternative approach for your migration.
Consult SAP Notes: Search for relevant SAP Notes in the SAP Support Portal that may address this specific error. There may be patches or updates that resolve known issues related to this error message.
Testing: After making changes, perform a test migration to ensure that the error does not reoccur and that the migration process can proceed smoothly.
Seek Expert Help: If you are unable to resolve the issue on your own, consider reaching out to SAP support or consulting with an SAP expert who has experience with data migration processes.
Related Information:
By following these steps, you should be able to address the CNV_PE179 error and proceed with your data migration or conversion tasks.
Get instant SAP help. Start your 7-day free trial now.
CNV_PE178
Parameter &1 is a structure; structure parameters are not allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_PE177
Parameter &1 is not a field
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_PE180
No parameter has to be activated
What causes this issue? Interface &V1& has no field parameters deactivated because of their name length. Therefore no parameter has to be act...
CNV_PE181
Parameter &1, scenario &2, REL entry missing
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.