Do you have any question about this error?
Message type: E = Error
Message class: CNV_CMIS_U_10 - CMIS Upg: Messages from table cascading functions
Message number: 074
Message text: Reading the MBT parameter file CNVMBTPARAMS successfully processed: &1,&2
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
CNV_CMIS_U_10074
- Reading the MBT parameter file CNVMBTPARAMS successfully processed: &1,&2 ?The SAP error message CNV_CMIS_U_10074 typically relates to issues encountered during the execution of a conversion program, particularly in the context of the SAP Conversion Management Information System (CMIS). This error indicates that there was a problem reading the MBT (Migration Business Tool) parameter file, which is essential for the conversion process.
Cause:
The error message suggests that the system was unable to read the specified MBT parameter file. This could be due to several reasons, including:
- File Not Found: The specified parameter file does not exist in the expected directory.
- File Permissions: The user or process attempting to read the file does not have the necessary permissions to access it.
- File Corruption: The parameter file may be corrupted or improperly formatted.
- Incorrect Path: The path to the parameter file may be incorrectly specified in the configuration.
- System Configuration Issues: There may be issues with the system configuration that prevent the file from being read.
Solution:
To resolve the CNV_CMIS_U_10074 error, you can take the following steps:
Verify File Existence: Check if the MBT parameter file exists in the specified location. If it does not, you may need to create or restore it.
Check File Permissions: Ensure that the user or process has the appropriate permissions to read the file. You may need to adjust the file permissions accordingly.
Inspect File Integrity: Open the parameter file to check for any corruption or formatting issues. If the file is corrupted, you may need to replace it with a valid version.
Confirm File Path: Double-check the configuration settings to ensure that the path to the parameter file is correct. Update the path if necessary.
Review System Logs: Look at the system logs for any additional error messages or warnings that may provide more context about the issue.
Consult Documentation: Refer to the SAP documentation or notes related to the specific conversion program you are using for any additional troubleshooting steps or requirements.
Contact SAP Support: If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the issue causing the CNV_CMIS_U_10074 error.
Get instant SAP help. Start your 7-day free trial now.
CNV_CMIS_U_10073
RFC destination error in function module &1 for package &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_CMIS_U_10072
RFC calling error in function module &1 for package &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_CMIS_U_10075
Reading the MBT parameter file CNVMBTPARAMS failed, rc: &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_CMIS_U_10076
Requested parameter not found in the table CNVMBTPARAMS, rc: &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.