Message type: E = Error
Message class: CNV_00001 - Message class for CWB settings maintenance programs
Message number: 211
Message text: Priority routine defined for table &1 although priority handling not used
Priority routine was defined for table &V1& in CNVSTEPS although
duplicate handling scenario is not 'Priority routine'. This setting has
no effect. The duplicate handling will be performed according to the
currently set duplicate handling method (CNVTABLES-SUMUP = '&V2&').
Priority routine definition in CNVSTEPS for table &V1& will be ignored.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CNV_00001211
- Priority routine defined for table &1 although priority handling not used ?The SAP error message CNV_00001211 indicates that there is a priority routine defined for a specific table, but the system is not using priority handling for that table. This message typically arises during data migration or conversion processes, particularly when using SAP's Data Migration tools or the SAP S/4HANA Migration Cockpit.
Cause:
The error occurs due to a mismatch between the configuration of the data migration process and the actual usage of priority handling. Specifically, it suggests that:
&1
), but the migration process is not set up to utilize that priority.To resolve this error, you can take the following steps:
Check Configuration: Review the configuration settings for the data migration process. Ensure that the priority handling is correctly set up if it is intended to be used.
Modify Priority Handling: If priority handling is not needed for the specific table, you can remove or disable the priority routine associated with that table. This can typically be done in the migration tool's configuration settings.
Review Migration Strategy: Ensure that the overall migration strategy aligns with the defined routines. If priority handling is not required, ensure that all related configurations reflect that.
Consult Documentation: Refer to the SAP documentation for the specific migration tool you are using. There may be additional guidelines or best practices regarding priority handling.
Testing: After making changes, conduct a test migration to ensure that the error is resolved and that the data is being processed as expected.
By following these steps, you should be able to address the CNV_00001211 error and ensure that your data migration process runs smoothly.
Get instant SAP help. Start your 7-day free trial now.
CNV_00001210
Irrelevant "Priority" flag set for one of the fields of table &1.
What causes this issue? "Prioritiy" flag was set for one of fields of table &V1&, however the the duplicate processing type is ...
CNV_00001209
Priority flag is set for more than one field of table &1.
What causes this issue? "Priority" flag is set for more than one field of table &V1&. The value of the field marked with the "...
CNV_00001212
For table &1 both "Copy" flag and "No temporary duplicates" flag set.
What causes this issue? For table &V1& both "Copy" flag and "No temporary duplicates" flag are set. This combination is n...
CNV_00001213
No temporary duplicates flag deleted for table &1.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.