Do you have any question about this error?
Message type: E = Error
Message class: CM_SUB_MLI - Messages for Multilevel Inheritance
Message number: 001
Message text: An inheriting spec. cannot at same time be a spec. that passes on data
You requested an inheritance for which the inheriting specification
matches the specification that passes on data. This is not possible,
however.
Enter a different specification as the source specification or target
specification.
Error message extract from SAP system. Copyright SAP SE.
CM_SUB_MLI001
- An inheriting spec. cannot at same time be a spec. that passes on data ?The SAP error message CM_SUB_MLI001 indicates that there is a conflict in the configuration of a specification in the SAP system, particularly in the context of the Classification Management (CM) module. This error typically arises when a specification is defined as both an inheriting specification and a specification that passes on data, which is not allowed.
Cause:
- Inheriting Specification: This type of specification is meant to inherit characteristics from another specification. It does not hold its own data but rather derives its attributes from a parent specification.
- Passing on Data: A specification that passes on data is expected to hold its own data and can be used to transfer data to other specifications or objects.
- Conflict: The error occurs because the system does not allow a specification to serve both roles simultaneously. A specification cannot inherit from another while also being responsible for passing on its own data.
Solution:
To resolve this error, you need to review the configuration of the specifications involved and make adjustments to ensure that a specification is either an inheriting specification or a specification that passes on data, but not both. Here are the steps you can take:
Review Specification Settings:
- Go to the specification in question and check its settings.
- Determine if it is set as an inheriting specification and if it is also marked to pass on data.
Modify Specification Type:
- If the specification is intended to inherit from another, ensure it is not set to pass on data. You may need to change its type or configuration.
- Conversely, if the specification is meant to pass on data, remove the inheriting designation.
Check Parent Specifications:
- If the specification is inheriting from a parent, ensure that the parent specification is correctly configured and does not have conflicting settings.
Test Changes:
- After making the necessary adjustments, test the changes to ensure that the error no longer occurs.
Documentation:
- Document the changes made for future reference and to assist other users who may encounter similar issues.
Related Information:
By following these steps, you should be able to resolve the CM_SUB_MLI001 error and ensure that your specifications are correctly configured in the SAP system.
Get instant SAP help. Start your 7-day free trial now.
CM_SUB_INFOSYS105
Program RC1H0XLS is no longer required
What causes this issue? You have attempted to execute program RC1H0XLS. It is no longer necessary, however, to save the macro for the Excel file to t...
CM_SUB_INFOSYS104
Error transferring data to Excel template
What causes this issue? The system cannot transfer the specification data to the Excel template because structure fields could not be assigned, for e...
CM_SUB_MLI002
Inheritance templates &1 and &2 have overlapping data areas
What causes this issue? You attempted to create an inheritance relationship to a target specification or source specification for which another inher...
CM_SUB_MLI003
Inheritance relationships were saved
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.