How To Fix CM_REPORT_GEN029 - Value assignment instance was not updated: foreign key RECNTVA &1


CM_REPORT_GEN029 - Overview

  • Message type: E = Error

  • Message class: CM_REPORT_GEN - Report Generation

  • Message number: 029

  • Message text: Value assignment instance was not updated: foreign key RECNTVA &1

  • Show details Hide details
  • What causes this issue?

    The value assignment instance output could not be updated in the control
    structure during final report generation for the following reason: &V2&
    Error Code,,Description of Reason
    A,,The value assignment instance of the specification could be read but
    is not active due to the usage. This value assignment instance was
    therefore not used to update the control structure.
    E,,A value assignment instance (foreign key RECNTVA &V1&) for the
    specification could not be assigned to the value assignment instance in
    the control structure.
    X,,The control structure was transferred to the target system using ALE.
    Foreign key RECNTVA &V1& of the value assignment instance could not be
    adjusted in the process. This occurs if the specification is not also
    transferred to the target system using ALE or is not transferred until
    after report body generation.

    System Response

    Final report generation continues. The data from report body generation
    is used for the value assignment instance of the affected control
    structure.

    How to fix this error?

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.

    Procedure for System Administrators


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message CM_REPORT_GEN029 - Value assignment instance was not updated: foreign key RECNTVA &1 ?
    The SAP error message CM_REPORT_GEN029 indicates that there was an issue with updating a value assignment instance due to a foreign key constraint violation. This typically occurs in the context of SAP's Environment, Health, and Safety (EHS) module or when dealing with material master data, where value assignment instances are used to manage various attributes of materials or substances.
    
    Cause: The error message "Value assignment instance was not updated: foreign key RECNTVA &1" suggests that the system attempted to update a value assignment instance, but the update failed due to a foreign key constraint. This can happen for several reasons: Missing Foreign Key Entry: The foreign key that the value assignment instance is trying to reference does not exist in the database. Data Inconsistency: There may be inconsistencies in the data, such as incorrect or incomplete entries in related tables. Authorization Issues: The user may not have the necessary permissions to update the value assignment

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant