Do you have any question about this error?
Message type: E = Error
Message class: CM_EHPSS_MGR -
Message number: 105
Message text: Specification &1: analytical composition could not be determined.
The system could not determine the analytical composition for
specification &V1& due to any of the following reasons:
The value assignment type "&V2&" does not exist in the specification.
The value assignment instance does not exist.
Several value assignment instances exist.
The component of the composition does not exist.
The system does not create the raw material for specification &V1&.
Check the value assignment type &V2& for specification &V1& in the
<DS:TRAN.CG02BD>Specification Workbench.</>
The specification must have the value assignment type &V2& with one
active instance.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CM_EHPSS_MGR105
- Specification &1: analytical composition could not be determined. ?The SAP error message CM_EHPSS_MGR105, which states "Specification &1: analytical composition could not be determined," typically occurs in the context of SAP's Environment, Health, and Safety (EHS) module, particularly when dealing with specifications and their analytical compositions.
Cause:
This error can arise due to several reasons, including:
- Missing Analytical Composition: The analytical composition for the specified material or specification is not defined in the system.
- Incorrect Configuration: There may be issues with the configuration of the specifications or the analytical composition in the system.
- Data Inconsistencies: There could be inconsistencies or missing data in the master data related to the material or specification.
- Authorization Issues: The user may not have the necessary authorizations to view or access the analytical composition data.
Solution:
To resolve this error, you can take the following steps:
Check Specification Data:
- Go to the specification in question and verify if the analytical composition is defined.
- Ensure that all required fields are filled out correctly.
Define Analytical Composition:
- If the analytical composition is missing, you may need to create or define it in the system. This can typically be done in the EHS module under the relevant specification management area.
Review Configuration:
- Check the configuration settings related to specifications and analytical compositions in the EHS module. Ensure that everything is set up correctly.
Data Consistency Check:
- Run data consistency checks to identify any inconsistencies in the master data that may be causing the issue.
Authorization Check:
- Ensure that the user encountering the error has the necessary authorizations to access the analytical composition data.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on managing specifications and analytical compositions.
Contact SAP Support:
- If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a solution.
Get instant SAP help. Start your 7-day free trial now.
CM_EHPSS_MGR104
Component &1 has an exceptional value. Component is not transferred.
What causes this issue? Component &V1& has the exceptional value &V4&.System Response The component is not transferred to the analyt...
CM_EHPSS_MGR103
Component &1 was not found in the analytical composition.
What causes this issue? Component "&V1&" was not found as a company substance.System Response The system does not create the raw m...
CM_EHPSS_MGR150
---for filling of unpackaged products -----------------------------------
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CM_EHPSS_MGR151
Internal system error occurred while mapping unpackaged products.
What causes this issue? You are trying to map specification data to new unpackaged products. An error occurs.System Response The system does not cre...
Click on this link to search all SAP messages.