Do you have any question about this error?
Message type: E = Error
Message class: CI_DRAFTPRD_MESSAGE -
Message number: 076
Message text: Unit of measure & not maintained for product &
You have chosen a unit of measure that does not yet exist in the product
master record.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Create the unit of measure as an alternative unit of measure in the
product master record.
Error message extract from SAP system. Copyright SAP SE.
CI_DRAFTPRD_MESSAGE076
- Unit of measure & not maintained for product & ?The SAP error message CI_DRAFTPRD_MESSAGE076 indicates that a unit of measure (UoM) has not been maintained for a specific product in the system. This error typically arises when you are trying to create or update a product in the SAP system, and the system cannot find a valid unit of measure associated with that product.
Cause:
- Missing Unit of Measure: The primary cause of this error is that the unit of measure for the specified product has not been defined in the system.
- Incorrect Product Configuration: The product may not have been properly configured in the material master or product master data.
- Data Inconsistency: There may be inconsistencies in the data, such as missing entries in related tables.
Solution:
To resolve this error, you can follow these steps:
Check Product Master Data:
- Go to the product master data (transaction code
MM03
for material master).- Enter the product number and check if the unit of measure is maintained in the relevant views (e.g., Basic Data, Sales, Purchasing).
Maintain Unit of Measure:
- If the unit of measure is missing, you can maintain it by using transaction code
MM01
(to create) orMM02
(to change).- Ensure that you enter the correct unit of measure in the appropriate fields.
Check UoM Settings:
- Ensure that the unit of measure is defined in the system. You can check this in the configuration settings (transaction code
OMN3
).- Make sure that the UoM is active and correctly linked to the product category.
Review Related Configuration:
- If the product is part of a specific product hierarchy or category, ensure that the UoM is maintained for that category as well.
Data Consistency Check:
- Run any relevant data consistency checks or reports to identify any other potential issues with the product data.
Consult Documentation:
- If you are unsure about the correct UoM to use, consult your organization's documentation or reach out to a colleague who manages product data.
Related Information:
MM01
, MM02
, MM03
, and OMN3
for managing material master data and unit of measure settings.By following these steps, you should be able to resolve the CI_DRAFTPRD_MESSAGE076 error and ensure that the unit of measure is properly maintained for the specified product.
Get instant SAP help. Start your 7-day free trial now.
CI_DRAFTPRD_MESSAGE075
Product & in SLoc & of plant & not maintained
What causes this issue? No data exists yet for product in storage location of plant . The system issues an error message and will not allow you to c...
CI_DRAFTPRD_MESSAGE074
Product & not maintained in plant &
What causes this issue? No product master data exists for product in plant . This may be for one of the following reasons: The system issues an error...
CI_DRAFTPRD_MESSAGE077
Valuation & & not maintained for product &
What causes this issue? You have called up a product master record that does not yet exist in valuation area for valuation type.System Response The ...
CI_DRAFTPRD_MESSAGE078
Ref. product & not maintained for stge loc. & in plant &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.