Do you have any question about this error?
Message type: E = Error
Message class: CHK_ENH - Messages for enhancement checks
Message number: 418
Message text: No TADIR entry found for composite enhancement spot &1
The central object catalog entry in the TADIR database table is missing
for the composite enhancement spot &V1&.
The software logistics tools need this entry.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CHK_ENH418
- No TADIR entry found for composite enhancement spot &1 ?The SAP error message CHK_ENH418 indicates that there is no TADIR entry found for a composite enhancement spot. This typically occurs when you are trying to activate or work with a composite enhancement spot that has not been properly defined or registered in the TADIR table, which is responsible for storing information about development objects in SAP.
Cause:
- Missing TADIR Entry: The composite enhancement spot you are trying to use does not have a corresponding entry in the TADIR table. This can happen if the enhancement spot was not created correctly or if it was deleted.
- Transport Issues: If the enhancement spot was transported from another system and the transport did not include the necessary entries, this error can occur.
- Incorrect Configuration: There may be a configuration issue where the enhancement spot is not properly linked to the relevant development objects.
Solution:
- Check TADIR Entries: Use transaction SE11 to check the TADIR table for the specific composite enhancement spot. You can do this by executing a query to see if the enhancement spot exists.
- Create or Recreate the Enhancement Spot: If the enhancement spot is missing, you may need to create it again using transaction SE80 or SE84. Ensure that you follow the correct steps to define the composite enhancement spot.
- Transport Request: If the enhancement spot was supposed to be transported, check the transport request to ensure that it includes all necessary objects. You may need to re-transport the enhancement spot.
- Check for Dependencies: Ensure that all dependent objects and enhancements are also correctly defined and activated.
- Consult Documentation: Review SAP documentation or notes related to enhancement spots for any specific requirements or known issues.
Related Information:
If the issue persists after trying the above solutions, consider reaching out to SAP support or consulting with a technical expert who specializes in SAP enhancements.
Get instant SAP help. Start your 7-day free trial now.
CHK_ENH417
Implementation &1 (version &2) has elements with identical "FULLNAME"
What causes this issue? The enhancement implementation &V1& (Version &V2&) contains enhancement implementation elements with an ident...
CHK_ENH416
Option &1 found in enhanced object &2, but not in enhancement spot &3
What causes this issue? The option &V1& is defined in the enhancement object &V4&, but it is not contained in the enhancement spott &...
CHK_ENH419
No TADIR entry found for composite enhancement implementation &1
What causes this issue? The central object catalog entry in the TADIR database table is missing for the composite enhancement implementation <(>...
CHK_ENH420
Enhancement implementation &1 does not exist (TADIR entry still exists)
What causes this issue? The enhancement implementation &V1& does not exist; however, the corresponding TADIR entry still exists.System Respon...
Click on this link to search all SAP messages.