Message type: E = Error
Message class: CE - CAPP messages
Message number: 356
Message text: Method &: For wor.cntr. &, std. value & should not be maintained
The value type &V4& is calculated using the method &V1& and transferred
into the standard value &V3&.
However, it was specified in work center &V2& that no value should be
entered for standard value &V3&.
You should check whether CAPP should be used to calculate standard
value &V3& in work center &V2& or
maintain the method and work center so they are compatible.
Error message extract from SAP system. Copyright SAP SE.
CE356
- Method &: For wor.cntr. &, std. value & should not be maintained ?The SAP error message CE356 typically indicates that there is an issue with the standard value for a work center in the context of production planning or cost accounting. This error occurs when the system detects that a standard value has been maintained for a work center that should not have one, based on the configuration or the specific settings of the work center.
Cause: Incorrect Configuration: The work center may be configured in a way that does not allow for standard values to be maintained. This could be due to the type of work center or the settings in the controlling area. Data Inconsistency: There may be inconsistencies in the data entered for the work center, such as incorrect parameters or missing information. Business Logic: The business logic defined in the system may dictate that certain work centers should not have standard values, possibly due to their nature (e.g., external services, non-standard operations).
Solution: Review
Get instant SAP help. Sign up for our Free Essentials Plan.
CE355
Method &: For work center &, you may not maintain std. value &
What causes this issue? The value type &V4& is calculated using the method &V1& and is transferred into the standard value &V3&am...
CE354
Method & has another parameter ID than work center &
What causes this issue? Method &V1& has the value type &V3& which is assigned to the standard value &V4&. However, the curren...
CE357
Meth. & and the operation have base quantities with diff. dimensions
What causes this issue? The base quantity of the method &V1& has the unit &V2& and the dimension &V3&. The unit of measure of...
CE358
Method &: Table & cannot be accessed
What causes this issue? A system error occurred due to an inconsistency in method &V1&.How to fix this error? INCLUDE NA_SYSAD1Error message...