Do you have any question about this error?
Message type: E = Error
Message class: C0 - PP-PI: Messages for PI Sheet and Syntax Checker
Message number: 323
Message text: - Error when assigning interface parameter &
This process instruction is of type "dynamic function call".
Using characteristic PPPI_IMPORT_PARAMETER, you assigned interface
parameter &V1& of the function module to the process instruction. This
assignment is invalid for one of the reasons below:
No export parameter &V1& is defined in the function module you want to
call.
Characteristic PPPI_IMPORT_PARAMETER is assigned parameter name &V1&
twice in the process instruction.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check and correct the assignment of parameters in the process
instruction.
Error message extract from SAP system. Copyright SAP SE.
C0323
- - Error when assigning interface parameter & ?The SAP error message C0323, which states "Error when assigning interface parameter &," typically occurs when there is an issue with the assignment of parameters in a function module or method interface. This error can arise due to various reasons, including data type mismatches, incorrect parameter names, or issues with the data being passed.
Causes:
- Data Type Mismatch: The data type of the variable being passed does not match the expected data type of the interface parameter.
- Incorrect Parameter Name: The parameter name used in the call does not match the name defined in the function module or method.
- Null or Uninitialized Variables: The variable being passed may be null or uninitialized, leading to assignment issues.
- Length Issues: The length of the data being passed may exceed the defined length of the parameter.
- Structure Mismatch: If a structure is being passed, the fields in the structure may not match the expected fields in the interface.
Solutions:
- Check Data Types: Ensure that the data types of the variables being passed match the expected data types of the interface parameters.
- Verify Parameter Names: Double-check the parameter names in the function module or method definition to ensure they are being called correctly.
- Initialize Variables: Make sure that all variables being passed are properly initialized before the call.
- Check Lengths: Ensure that the length of the data being passed does not exceed the defined length of the interface parameters.
- Review Structures: If using structures, verify that the fields in the structure match the expected fields in the interface.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the C0323 error in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
C0322
- Characteristic & & cannot be used in this position
INCLUDE C0321 OBJECT DOKU ID NA LANGUAGE E The system issues an error message and will not allow you to continue with this transaction until the erro...
C0321
- Characteristic & & cannot be used in this position
What causes this issue? This process instruction is of type "dynamic function call". Immediately before characteristic &V1& &V2...
C0324
- Error when assigning interface parameter &
What causes this issue? This process instruction is of type "dynamic function call". Using characteristic PPPI_EXPORT_PARAMETER, you assign...
C0325
- Error when assigning interface parameter &
What causes this issue? This process instruction is of type "dynamic function call". Using characteristic PPPI_CHANGING_PARAMETER, you assi...
Click on this link to search all SAP messages.