Message type: E = Error
Message class: BWFS_TECHNICAL - Technical Interface BW/FS
Message number: 003
Message text: No initialization with InfoSource &1 and selection &2
The position initialization (InfoSource &V1&) has already been run
with the selection &V2& .
The position initialization is terminated.
The following options are available:
You reset the position initialization for the selection &V2&.
You schedule the delta initialization for the selection &V2&.
You change the Infopackage so that the selection &V2& can no longer
occur.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BWFS_TECHNICAL003
- No initialization with InfoSource &1 and selection &2 ?The SAP error message BWFS_TECHNICAL003 indicates that there is an issue with the initialization of a data source in SAP BW (Business Warehouse). This error typically occurs when the system is unable to initialize data from a specific InfoSource due to various reasons.
Cause: Missing or Incorrect InfoSource: The specified InfoSource (&1) may not exist or may not be correctly configured in the system. Selection Criteria Issues: The selection criteria (&2) provided for the initialization may be incorrect or not applicable. Data Source Not Activated: The data source might not be activated or might be in a state that prevents initialization. Authorization Issues: The user executing the initialization may not have the necessary authorizations to access the InfoSource or the underlying data. Data Transfer Process (DTP) Issues: There may be issues with the DTP settings or the DTP itself may not be correctly configured. Technical Issues: There could be underlying technical issues such as connectivity problems, system
Get instant SAP help. Sign up for our Free Essentials Plan.
BWFS_TECHNICAL002
A Customizing entry is missing for the InfoSource &1 in table &2
What causes this issue? A Customizing entry is missing for the InfoSource in one of the following tables: BWFS_SETTINGS_01: InfoSources for Position ...
BWFS_TECHNICAL001
Invalid selection criterion in the interface
What causes this issue? Function module &V1& contains an invalid selection criterion for the application-dependent selection. Only one indivi...
BWFS_TECHNICAL004
There is more than one position initialization for InfoSource &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BWFS_TECHNICAL005
Table &1 locked with argument &2
What causes this issue? The table &V1& should have been locked for data extraction with the loc argument &V2&. This was not possible....
Click on this link to search all SAP messages.